Literature DB >> 7795380

Reliability of electron beam computed tomography to detect coronary artery calcification.

J P Shields1, C H Mielke, T H Rockwood, R A Short, F K Viren.   

Abstract

Electron beam computed tomography (CT) provides a safe, rapid, and noninvasive means to detect the presence and quantitate the deposition of calcium in the coronary arteries. To examine the reproducibility of a coronary calcification screen using electron beam CT, 50 subjects underwent two studies, averaging 12 minutes between studies. The number, volume, and calcification scores were determined for each artery as well as a total score of coronary calcification. Thirty-four of the 50 subjects had evidence of coronary calcification. The reliability score for total coronary artery calcification was 0.99. The reliability score for the total number of lesions and total volume was at or above 0.98. There were 8 cases in which a negative calcium score on retest was positive or where a positive calcium score on retest was negative. In both instances, the amount of calcium detected was very small. Therefore, evidence suggests that electron beam CT is reliable in the detection of coronary artery calcification and may be a useful tool for the early detection of coronary atherosclerosis before flow impairment.

Entities:  

Mesh:

Year:  1995        PMID: 7795380

Source DB:  PubMed          Journal:  Am J Card Imaging        ISSN: 0887-7971


  8 in total

1.  Assessment of calcium scoring performance in cardiac computed tomography.

Authors:  Stefan Ulzheimer; Willi A Kalender
Journal:  Eur Radiol       Date:  2002-12-04       Impact factor: 5.315

2.  Reproducibility of three different scoring systems for measurement of coronary calcium.

Authors:  Hideya Yamamoto; Matthew J Budoff; Bin Lu; Junichiro Takasu; Ronald J Oudiz; Songshou Mao
Journal:  Int J Cardiovasc Imaging       Date:  2002-10       Impact factor: 2.357

Review 3.  Potential use of Ca++ scanning to determine the need for and intensity of lipid-lowering therapy in asymptomatic adults.

Authors:  A D Guerci; Y Arad
Journal:  Curr Cardiol Rep       Date:  2001-09       Impact factor: 2.931

Review 4.  Electron beam computed tomography: screening for coronary artery disease.

Authors:  M J Budoff; B H Brundage
Journal:  Clin Cardiol       Date:  1999-09       Impact factor: 2.882

Review 5.  Update on using coronary calcium screening by computed tomography to measure risk for coronary heart disease.

Authors:  Brad H Thompson; William Stanford
Journal:  Int J Cardiovasc Imaging       Date:  2005-02       Impact factor: 2.357

Review 6.  MDCT: cardiology indications.

Authors:  Andreas F Kopp; Axel Küttner; Tobias Trabold; Martin Heuschmid; Stephen Schröder; C D Claussen
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 7.034

Review 7.  Screening for Ischemic Heart Disease with Cardiac CT: Current Recommendations.

Authors:  Matthew J Budoff
Journal:  Scientifica (Cairo)       Date:  2012-09-18

8.  Fluorescent Arylphosphonic Acids: Synergic Interactions between Bone and the Fluorescent Core.

Authors:  Yunus Zorlu; Connor Brown; Claudia Keil; M Menaf Ayhan; Hajo Haase; Richard B Thompson; Imre Lengyel; Gündoğ Yücesan
Journal:  Chemistry       Date:  2020-07-28       Impact factor: 5.236

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.