Literature DB >> 7793780

Anthropometric optical surface imaging system repeatability, precision, and validation.

L A Kohn1, J M Cheverud, G Bhatia, P Commean, K Smith, M W Vannier.   

Abstract

Disciplines using human body surface dimensions require accurate, repeatable measurements. This study presents a design for the analysis of repeatability, precision, and validation of a new anthropometric device. This model enables estimation of the proportion of the total variation attributable to each level of data collection. This model is applied to an analysis of repeatability, precision, and validation of the Cencit Imaging System, a new optical surface scanner. Twenty-seven facial landmarks were marked on 10 men and 10 women at two measurement sessions. Two images were scanned during each session, and each image was digitized twice. The Cencit Imaging System results were compared with a previously validated digitizer. The Cencit Imaging System was found to produce accurate, highly repeatable images. Much of the error in this study is attributable to human error in marking landmarks on the subjects. The new imaging system will prove useful in a variety of anthropometric applications.

Entities:  

Mesh:

Year:  1995        PMID: 7793780     DOI: 10.1097/00000637-199504000-00004

Source DB:  PubMed          Journal:  Ann Plast Surg        ISSN: 0148-7043            Impact factor:   1.539


  4 in total

1.  Precision and error of three-dimensional phenotypic measures acquired from 3dMD photogrammetric images.

Authors:  Kristina Aldridge; Simeon A Boyadjiev; George T Capone; Valerie B DeLeon; Joan T Richtsmeier
Journal:  Am J Med Genet A       Date:  2005-10-15       Impact factor: 2.802

2.  Evaluation of precision and accuracy assessment of different 3-D surface imaging systems for biomedical purposes.

Authors:  Maximilian Eder; Gernot Brockmann; Alexander Zimmermann; Moschos A Papadopoulos; Katja Schwenzer-Zimmerer; Hans Florian Zeilhofer; Robert Sader; Nikolaos A Papadopulos; Laszlo Kovacs
Journal:  J Digit Imaging       Date:  2013-04       Impact factor: 4.056

3.  Postcranial Skeletal Differences in Free-Range and Captive-Born Primates.

Authors:  Luci Ann P Kohn; Gabriele R Lubach
Journal:  Anat Rec (Hoboken)       Date:  2018-11-09       Impact factor: 2.064

4.  Soft-tissue thickness of South Korean adults with normal facial profiles.

Authors:  Kyung-Suk Cha
Journal:  Korean J Orthod       Date:  2013-08-22       Impact factor: 1.372

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.