Literature DB >> 7793721

Iron overdose and detection of gastrointestinal bleeding with the hemoccult and gastroccult assays.

C L Tunget1, R F Clark, A S Manoguerra, S G Turchen.   

Abstract

STUDY
OBJECTIVE: To determine the ability of the Hemoccult and Gastroccult tests (SmithKline Diagnostics) to detect blood in vitro in whole-bowel irrigation (WBI) solution.
INTERVENTIONS: One tablet of ferrous gluconate 324 mg, ferrous sulfate 325 mg, or ascorbic acid 500 mg; or one Materna prenatal vitamin tablet (Lederle Laboratories) was dissolved in 30 mL of Colyte. Colyte alone and each test solution were tested with Hemoccult and Gastroccult slides, then retested at pH values of 3 and 8. Fresh solutions were then spiked with blood and tested with Gastroccult slides. Materna and ascorbic acid solutions were spiked with blood, then tested with Hemoccult slides.
RESULTS: Positive results were difficult to detect on Gastroccult slides. Hemoccult slides were falsely positive for solutions containing only iron and falsely negative for blood-spiked samples containing ascorbic acid.
CONCLUSION: Both the Hemoccult and Gastroccult tests may be unreliable in detecting GI bleeding in cases of iron overdose treated with WBI.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7793721     DOI: 10.1016/s0196-0644(95)70238-5

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  1 in total

Review 1.  Are medication restrictions before FOBT necessary?: practical advice based on a systematic review of the literature.

Authors:  Gerald Konrad; Alan Katz
Journal:  Can Fam Physician       Date:  2012-09       Impact factor: 3.275

  1 in total