Abstract

This study aimed to develop a protocol for assessing the influence of movement on oxyhaemoglobin saturation readings from pulse oximeters. Thirty-six volunteers took part in the study. In each volunteer, each hand was monitored by both a Nellcor N200 oximeter using a disposable probe and by a Datex Satlite DS103 oximeter using a clip-on finger probe. Volunteers made five standardised movements during which output was recorded from all four oximeters. All movements were associated with apparent decreases in oxyhaemoglobin saturation which were statistically significant for two movements with the Nellcor equipment and for four movements with the Datex equipment. Movement was associated with increases in the magnitude of pulse amplitude, but this was not quantitatively associated with magnitude of artefactual changes in saturation. Use of this standardised movement protocol allows quantification of movement artefact from pulse oximeters and should facilitate the development of equipment less affected by movement.

Mesh:

Substances:

Year:  1995        PMID: 7793549     DOI: 10.1111/j.1365-2044.1995.tb05998.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  4 in total

1.  Identification of movement artefact by the Nellcor N-200 and N-3000 pulse oximeters.

Authors:  J L Plummer; A H Ilsley; R R Fronsko; H Owen
Journal:  J Clin Monit       Date:  1997-03

Review 2.  Pulmonary gas exchange and acid-base balance during exercise.

Authors:  Michael K Stickland; Michael I Lindinger; I Mark Olfert; George J F Heigenhauser; Susan R Hopkins
Journal:  Compr Physiol       Date:  2013-04       Impact factor: 9.090

3.  Design Rationale and Performance Evaluation of the Wavelet Health Wristband: Benchtop Validation of a Wrist-Worn Physiological Signal Recorder.

Authors:  Onur Dur; Reinier van Mourik; Colleen Rhoades; Man Suen Ng; Ragwa Elsayed; Maulik D Majmudar
Journal:  JMIR Mhealth Uhealth       Date:  2018-10-16       Impact factor: 4.773

4.  Feasibility and reliability of an automated controller of inspired oxygen concentration during mechanical ventilation.

Authors:  Kaouther Saihi; Jean-Christophe M Richard; Xavier Gonin; Thomas Krüger; Michel Dojat; Laurent Brochard
Journal:  Crit Care       Date:  2014-02-19       Impact factor: 9.097