CT-guided automated needle biopsy of the chest.

L B Haramati1.   

Abstract

OBJECTIVE: The purpose of this study was to determine the diagnostic accuracy and frequency of complications of CT-guided transthoracic needle biopsy done with an automated biopsy system.
MATERIALS AND METHODS: Thirty-three consecutive biopsies were performed on 32 patients between February 1992 and July 1994 (mean age, 55 +/- 15 years; 18 men and 14 women). An 18-gauge (n = 28) or 20-gauge (n = 5) needle was used. Core specimens were submitted for pathologic examination in 10% formalin. No cytopathologist or frozen section analysis was available at the time of biopsy. All biopsies but one were performed by one chest radiologist.
RESULTS: Thirty-one lung biopsies and two mediastinal biopsies yielded a mean lesion size of 4.0 cm (range, 1.2-13.0 cm). Postbiopsy pneumothorax occurred in three (9%) of 33 biopsies; none of the pneumothoraces required placement of a chest tube. The mean number of needle passes was 1.3 (+/- 0.6). Thirty biopsies (91%) yielded sufficient tissue for pathologic evaluation. The diagnoses included carcinoma in 14 cases, acute or chronic pneumonia in 4 cases, non-Hodgkin's lymphoma in two cases, and Kaposi's sarcoma, plasma cell granuloma, hypersensitivity pneumonitis, Pneumocystis carinii pneumonia, and fibrosis in one case each. One patient with a 1.5-cm nodule stable for 1 year on CT had fibrosis and chronic inflammation found on needle biopsy, and the nodule was considered benign. Overall, biopsies in 12 (80%) of 15 patients without carcinoma were diagnostic. In three patients, the tissue obtained was not representative of the underlying abnormality. The biopsy specimen showed only inflammatory changes in two patients who ultimately had proved carcinoma. One patient with multiple pulmonary infarcts due to tumor emboli showed evidence of only pulmonary infarct on biopsy. Three patients had insufficient tissue for analysis; none of the three had malignant tumor on follow-up. The sensitivity of CT-guided automated needle biopsy of the chest was 84%.
CONCLUSION: CT-guided transthoracic needle biopsy of the chest done with an automated biopsy system is safe, with a pneumothorax rate comparable to that of skinny needle aspiration. An overall accurate tissue diagnosis was made in 26 (81%) of 32 patients. Biopsies in 12 (80%) of 15 patients without carcinoma were diagnostic, which compares favorably with the reported accuracy of skinny needle aspiration.

Entities:  

Mesh:

Year:  1995        PMID: 7785631     DOI: 10.2214/ajr.165.1.7785631

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  11 in total

1.  Percutaneous transthoracic needle biopsy: special considerations and techniques used in lung transplant recipients.

Authors:  Amanda B Wallace; Robert D Suh
Journal:  Semin Intervent Radiol       Date:  2004-12       Impact factor: 1.513

2.  Comparison of fully automated and semi-automated biopsy needles for lung biopsy under CT fluoroscopic guidance.

Authors:  R Yoshimatsu; T Yamagami; O Tanaka; H Miura; T Tanaka; T Suzuki; T Nishimura
Journal:  Br J Radiol       Date:  2011-08-09       Impact factor: 3.039

3.  Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy.

Authors:  Takuji Yamagami; Rika Yoshimatsu; Kenji Kajiwara; Masaki Ishikawa; Tomohiro Matsumoto; Hideaki Kakizawa; Naoyuki Toyoda; Terumitsu Hasebe; Kazuo Awai
Journal:  Eur Radiol       Date:  2014-02-14       Impact factor: 5.315

Review 4.  Percutaneous lung biopsy: technique, efficacy, and complications.

Authors:  Ronald S Winokur; Bradley B Pua; Brian W Sullivan; David C Madoff
Journal:  Semin Intervent Radiol       Date:  2013-06       Impact factor: 1.513

5.  Value of CT-guided core-needle biopsy in diagnosis and classification of malignant lymphomas using automated biopsy gun.

Authors:  Li Li; Qiu-Liang Wu; Li-Zhi Liu; Yun-Xian Mo; Chuan-Miao Xie; Lie Zheng; Lin Chen; Pei-Hong Wu
Journal:  World J Gastroenterol       Date:  2005-08-21       Impact factor: 5.742

6.  Guidelines for the investigation of invasive fungal infections in haematological malignancy and solid organ transplantation. British Society for Medical Mycology.

Authors:  D W Denning; E G Evans; C C Kibbler; M D Richardson; M M Roberts; T R Rogers; D W Warnock; R E Warren
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1997-06       Impact factor: 3.267

7.  Percutaneous transthoracic needle biopsy for pulmonary nodules: a retrospective study of a comparison between C-arm cone-beam computed tomography and conventional computed tomography guidance.

Authors:  Surasit Akkakrisee; Keerati Hongsakul
Journal:  Pol J Radiol       Date:  2020-06-18

8.  Diagnostic performance of percutaneous lung biopsy using automated biopsy needles under CT-fluoroscopic guidance for ground-glass opacity lesions.

Authors:  T Yamagami; R Yoshimatsu; H Miura; K Yamada; A Takahata; T Matsumoto; T Hasebe
Journal:  Br J Radiol       Date:  2013-02       Impact factor: 3.039

9.  Diagnostic accuracy and complications of CT-guided core needle lung biopsy of solid and part-solid lesions.

Authors:  Sam Yun; Hee Kang; Sekyoung Park; Beom Su Kim; Jung Gu Park; Min Jung Jung
Journal:  Br J Radiol       Date:  2018-06-01       Impact factor: 3.039

10.  Thoracoscopic needle aspiration biopsy for a centrally located solitary pulmonary nodule.

Authors:  Ho Kyung Sung; Hyun Koo Kim; Young Ho Choi
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2013-08-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.