Implantable cardioverter defibrillator lead technology: improved performance and lower defibrillation thresholds.

D J Lang1, J E Heil, S J Hahn, C C Lindstrom, D L Derfus.   

Abstract

The performance of an ICD system depends, in part, on the effectiveness with which the lead system functions. Engineering trade-offs are made during the design of a lead to optimize one or more performance characteristics: e.g., lead handling, fatigue life, size, and optimized therapy delivery. To assure low defibrillation thresholds, careful attention must be taken during the design process to prevent these trade-offs from hampering the lead's therapy effectiveness. Four basic design rules are described that capture many of the engineering concepts that will enhance a lead's efficacy: (1) minimize electrode pullback, (2) deliver current to the apex, (3) minimize energy loss in the lead, and (4) use large, efficient electrodes. These rules speak to optimizing delivery of current to the heart and efficiency of the lead and electrode interface. When the lead performs its function well, the complete ICD system of the heart, lead, and implantable pulse generator will provide optimal safety margins for device implant and an increased number of patients that can be implanted with a single-lead system.

Entities:  

Mesh:

Year:  1995        PMID: 7777419     DOI: 10.1111/j.1540-8159.1995.tb02565.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  Spatial potential and current distributions along transvenous defibrillation electrodes: variation of electrode characteristics.

Authors:  R Pendekanti; C S Henriquez
Journal:  Ann Biomed Eng       Date:  1996 Jan-Feb       Impact factor: 3.934

2.  [Influence of waveform and configuration of electrodes on the defibrillation threshold of implantable cardioverter-defibrillators].

Authors:  M Block; D Hammel; G Breithardt
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-03

3.  Effect of shock polarity on defibrillation thresholds with a hybrid patch-coil lead system.

Authors:  Eric J Rashba; Stephen R Shorofsky; Robert W Peters; Michael R Gold
Journal:  J Interv Card Electrophysiol       Date:  2003-12       Impact factor: 1.900

Review 4.  Integrated approach for smart implantable cardioverter defibrillator (ICD) device with real time ECG monitoring: use of flexible sensors for localized arrhythmia sensing and stimulation.

Authors:  Munish Puri; Kalyan C Chapalamadugu; Aimon C Miranda; Shyam Gelot; Wilfrido Moreno; Prashanth C Adithya; Catherine Law; Srinivas M Tipparaju
Journal:  Front Physiol       Date:  2013-10-24       Impact factor: 4.566