Literature DB >> 7774323

Accuracy of end-tidal and transcutaneous PCO2 monitoring during sleep.

M H Sanders1, N B Kern, J P Costantino, R A Stiller, P J Strollo, K A Studnicki, J A Coates, T J Richards.   

Abstract

STUDY
OBJECTIVE: Although it is intuitively desirable, the measurement of arterial carbon dioxide tension (PaCO2) during diagnostic polysomnography and nocturnal trials of positive pressure therapy is invasive and potentially expensive. The accuracy of end-tidal carbon dioxide tension (PETCO2) and transcutaneous carbon dioxide (tcPCO2) monitoring in these contexts has not been systematically evaluated. This investigation was undertaken to evaluate the accuracy of PETCO2 and tcPCO2 in patients undergoing polysomnography. METHODS AND PROCEDURES: Values of PETCO2 were compared with PaCO2 in 19 patients spontaneously breathing room air (condition 1), in 13 patients receiving supplemental oxygen via nasal cannula (condition 2), and in 22 patients receiving nocturnal positive pressure ventilatory assistance (all but one with continuous positive airway pressure or bilevel positive airway pressure) (condition 3). The accuracy of tcPCO2 monitoring during sleep was also examined by comparing tcPCO2 values with simultaneously recorded PaCO2 values obtained during sleep in patients undergoing nocturnal polysomnography. Data were collected using three commercially available brands of tcPCO2 monitors (capnograph R, n = 17 patients; capnograph S, n = 17; and capnograph N, n = 15).
RESULTS: Accuracy of PETCO2--There was significant scatter in the PaCO2 vs PETCO2 relationship such that only 23 percent of the variability in PaCO2 was explained by variation of PETCO2 during condition 1 and only 15 percent and 20 percent of the variability in PaCO2 was explained by variation of PETCO2 during conditions 2 and 3, respectively. 21.3 percent of patients had average PETCO2 values in error by > 10 mm Hg during condition 1, while during conditions 2 and 3, 46.2 and 63.7 percent of patients had average values in error by > 10 mm Hg, respectively. Accuracy of tcPCO2--While capnographs S and N generally overestimated PaCO2 with a wide scatter, capnograph R tended to have offsetting overestimations and underestimations of PaCO2 with a wide scatter. With each capnograph, a relatively small portion of the variability of the PaCO2 was explained by variability of the tcPCO2 (r2 = 0.2, 0.45 and 0.64 for capnographs S, N, and R, respectively). Across the three capnographs, 43.1 to 66.7 percent of measurements were in error by > 10 mm Hg, and 5 to 20 percent of measurements reflected errors > 20 mm Hg. There was no consistent relationship between the tcPCO2 error and the level of PaCO2, nor was the tcPCO2 error consistent in individual patients. There was no relationship between tcPCO2 accuracy and body mass index.
CONCLUSION: Neither PETCO2, measured within a face mask, nor tcPCO2 is a consistently accurate reflection of PaCO2. This limits the utility of these variables in monitoring patients during diagnostic and therapeutic sleep studies, and in particular, during trials of nocturnal ventilatory assistance where adequate levels of support are to be established and unacceptable hyperventilation and respiratory alkalosis must be recognized.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7774323     DOI: 10.1378/chest.106.2.472

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  15 in total

Review 1.  Hyperventilation in panic disorder and asthma: empirical evidence and clinical strategies.

Authors:  Alicia E Meuret; Thomas Ritz
Journal:  Int J Psychophysiol       Date:  2010-05-25       Impact factor: 2.997

2.  Utility of Transcutaneous Capnography for Optimization of Non-Invasive Ventilation Pressures.

Authors:  Prashant N Chhajed; Simone Gehrer; Kamlesh V Pandey; Preyas J Vaidya; Joerg D Leuppi; Michael Tamm; Werner Strobel
Journal:  J Clin Diagn Res       Date:  2016-09-01

3.  Are nocturnal hypoxemia and hypercapnia associated with desaturation immediately after adenotonsillectomy?

Authors:  Nicholas M Dalesio; Douglas H McMichael; James R Benke; Sean Owens; Kathryn A Carson; Deborah A Schwengel; Alan R Schwartz; Stacey L Ishman
Journal:  Paediatr Anaesth       Date:  2015-04-09       Impact factor: 2.556

4.  Neurodevelopmental Outcomes at Two Years of Age for Premature Infants Diagnosed With Neonatal Obstructive Sleep Apnea.

Authors:  Anuja Bandyopadhyay; Heidi Harmon; James E Slaven; Ameet S Daftary
Journal:  J Clin Sleep Med       Date:  2017-11-15       Impact factor: 4.062

Review 5.  Sleep disorders in chronic obstructive pulmonary disease: etiology, impact, and management.

Authors:  Rohit Budhiraja; Tauseef A Siddiqi; Stuart F Quan
Journal:  J Clin Sleep Med       Date:  2015-03-15       Impact factor: 4.062

6.  Polysomnographic determinants of nocturnal hypercapnia in patients with sleep apnea.

Authors:  Nattapong Jaimchariyatam; Raed A Dweik; Roop Kaw; Loutfi S Aboussouan
Journal:  J Clin Sleep Med       Date:  2013-03-15       Impact factor: 4.062

7.  Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine.

Authors:  Richard B Berry; Rohit Budhiraja; Daniel J Gottlieb; David Gozal; Conrad Iber; Vishesh K Kapur; Carole L Marcus; Reena Mehra; Sairam Parthasarathy; Stuart F Quan; Susan Redline; Kingman P Strohl; Sally L Davidson Ward; Michelle M Tangredi
Journal:  J Clin Sleep Med       Date:  2012-10-15       Impact factor: 4.062

8.  Carbon dioxide monitoring during laparoscopic-assisted bariatric surgery in severely obese patients: transcutaneous versus end-tidal techniques.

Authors:  Joanna M Dion; Chris McKee; Joseph D Tobias; Daniel Herz; Paul Sohner; Steven Teich; Marc Michalsky
Journal:  J Clin Monit Comput       Date:  2014-06-11       Impact factor: 2.502

9.  Comparative provocation test of respiratory monitoring methods.

Authors:  Mia Folke; Fredrik Granstedt; Bertil Hök; Håkan Scheer
Journal:  J Clin Monit Comput       Date:  2002-02       Impact factor: 2.502

10.  Clinical commentary: obstetric and respiratory management of pregnancy with severe spinal muscular atrophy.

Authors:  Daniel Flunt; Natasha Andreadis; Collette Menadue; Alec W Welsh
Journal:  Obstet Gynecol Int       Date:  2009-05-19
View more