Chemical compatibility of inotropic and vasoactive agents delivered via a multiple line infusion system.

J A Grillo1, E R Gonzalez, A Ramaiya, H T Karnes, B Wells.   

Abstract

OBJECTIVES: To determine the chemical compatibility of three different triple drug admixtures diluted with either 5% dextrose in water or 0.9% NaCl solution when administered via a multiple line infusion system (Omni-Flow 4000, Abbott Laboratories, Abbott Park, IL). The triple drug admixtures were: a) dobutamine, dopamine, and norepinephrine; b) nitroglycerin, sodium nitroprusside, and dobutamine; and c) nitroglycerin, dopamine, and dobutamine.
DESIGN: Two phase in vitro compatibility study.
SETTING: Pharmaceutical laboratory.
SUBJECTS: None.
INTERVENTIONS: Phase I assessed chemical stability when the triple drug admixture was placed in a single container. In phase II, individual drug components of the admixtures were infused via the multiple line infusion system. Samples were collected at time 0, 1 hr, 2 hrs, 4 hrs, 12 hrs, and 24 hrs. All samples were frozen and stored at -70 degrees C until assayed.
MEASUREMENTS AND MAIN RESULTS: Samples were assayed using stability-indicating high performance liquid chromatography. The triple drug admixtures were considered to be chemically stable if there was < or = 10% loss of stated potency over 24 hrs. In phase I, chemical stability was observed for all triple drug admixtures at 24 hrs. In phase II, dobutamine, dopamine, norepinephrine, and sodium nitroprusside showed chemical stability at 24 hrs. Nitroglycerin showed a two-fold increase in concentration at 24 hrs compared with the initial concentration through the test infusion system; however, this amount was still one third lower than originally anticipated.
CONCLUSIONS: All triple drug admixtures were chemically stable when placed in single containers. Dobutamine, norepinephrine, and sodium nitroprusside showed chemical stability when delivered via a multiple line infusion system. The reduced recovery of nitroglycerin from the test infusion system may result from adsorption of the nitroglycerin to the polyvinyl chloride plastic cassette and tubing during infusion.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7774217     DOI: 10.1097/00003246-199506000-00011

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  2 in total

1.  Stability of norepinephrine solutions in normal saline and 5% dextrose in water.

Authors:  Scott E Walker; Shirley Law; Jill Garland; Esther Fung; John Iazzetta
Journal:  Can J Hosp Pharm       Date:  2010-03

2.  Understanding the Stability of Dopamine and Dobutamine Over 24 h in Simulated Neonatal Ward Conditions.

Authors:  Katherine Kirupakaran; Liam Mahoney; Heike Rabe; Bhavik A Patel
Journal:  Paediatr Drugs       Date:  2017-10       Impact factor: 3.022

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.