Literature DB >> 7764043

Real-time measurement of anchorage-dependent cell adhesion using a quartz crystal microbalance.

D M Gryte1, M D Ward, W S Hu.   

Abstract

An in situ technique based on the mass-sensitive piezoelectric quartz crystal microbalance (QCM) was applied to continuously monitor the attachment and detachment of anchorage-dependent mammalian cells on a metal surface. Specifically, we have demonstrated that the attachment of Vero cells to metal surfaces on the piezoelectrically active area of the QCM results in decreases in the QCM resonant frequency that can be monitored conveniently in real time. Lysis and detachment of Vero cells caused by vesicular stomatitis virus (VSV) infection can also be monitored readily. Our results demonstrate that the QCM is a viable technique for monitoring anchorage-dependent cell attachment and detachment on surfaces (caused by stimulatory, inhibitory, or cytopathic effects).

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 7764043     DOI: 10.1021/bp00019a016

Source DB:  PubMed          Journal:  Biotechnol Prog        ISSN: 1520-6033


  8 in total

1.  Analysis of the composite response of shear wave resonators to the attachment of mammalian cells.

Authors:  J Wegener; J Seebach; A Janshoff; H J Galla
Journal:  Biophys J       Date:  2000-06       Impact factor: 4.033

Review 2.  Acoustic sensors as a biophysical tool for probing cell attachment and cell/surface interactions.

Authors:  Michael Saitakis; Electra Gizeli
Journal:  Cell Mol Life Sci       Date:  2011-10-15       Impact factor: 9.261

3.  Profiling of molecular interactions in real time using acoustic detection.

Authors:  Benjamin Godber; Mark Frogley; Marian Rehak; Alexander Sleptsov; Kevin S J Thompson; Yildiz Uludag; Matthew A Cooper
Journal:  Biosens Bioelectron       Date:  2006-11-28       Impact factor: 10.618

Review 4.  Studying Soft Interfaces with Shear Waves: Principles and Applications of the Quartz Crystal Microbalance (QCM).

Authors:  Diethelm Johannsmann; Arne Langhoff; Christian Leppin
Journal:  Sensors (Basel)       Date:  2021-05-17       Impact factor: 3.576

5.  Comparison of cultured cell attachment on a temperature-responsive polymer, poly-L-lysine, and collagen using modeling curves and a thermal-controlled quartz crystal microbalance.

Authors:  Abdullah Hussain A Alsaleem; Sae Ito; Kiyoshi Naemura; Hiroshi Muramatsu
Journal:  J Biol Phys       Date:  2021-04-24       Impact factor: 1.560

6.  Synchronized cell attachment triggered by photo-activatable adhesive ligands allows QCM-based detection of early integrin binding.

Authors:  Jagoba Iturri; Luis García-Fernández; Ute Reuning; Andrés J García; Aránzazu del Campo; Marcelo J Salierno
Journal:  Sci Rep       Date:  2015-03-31       Impact factor: 4.379

7.  Evaluating Inhibition of the Epidermal Growth Factor (EGF)-Induced Response of Mutant MCF10A Cells with an Acoustic Sensor.

Authors:  Marcela P Garcia; Ammar Shahid; Jennifer Y Chen; Jun Xi
Journal:  Biosensors (Basel)       Date:  2012-11-13

8.  Radiation-Activated Pre-Differentiated Retinal Tissue Monitored by Acoustic Wave Biosensor.

Authors:  Alin Cheran; Michael Thompson
Journal:  Sensors (Basel)       Date:  2020-05-05       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.