Literature DB >> 7762501

Circadian variation of ventricular arrhythmia recurrences after cardioverter-defibrillator implantation in patients with healed myocardial infarcts.

C Mallavarapu1, S Pancholy, D Schwartzman, D J Callans, J Heo, C D Gottlieb, F E Marchlinski.   

Abstract

Past studies using Holter monitoring and retrospective reviews of death certificates have documented peak occurrence of sudden death and nonsustained ventricular tachycardia (VT) in the morning hours. We used the Ventritex Cadence device (Ventritex, Sunnyvale, California) which documents the date and time of all stored arrhythmias leading to device therapy to evaluate the circadian pattern of sustained ventricular arrhythmia recurrence. Mean follow-up after defibrillator implantation was 628 +/- 285 days. All 390 patients had at least 1 episode (range 1 to 43) of sustained VT documented from analysis of the stored electrograms associated with an arrhythmia event. Stored electrograms were available for review and analysis in 3,041 device detections; 349 stored events were excluded because they did not fulfill the diagnostic criteria for VT or failed to document the onset of the ventricular arrhythmia at the beginning of the recorded event of the arrhythmia episode. Criteria for the diagnosis of VT or ventricular fibrillation were met in 2,692 arrhythmia episodes occurring in 390 patients. There was circadian variation for ventricular arrhythmia recurrence for the whole patient group with the data fit to the sinusoidal density function: f(t) = 126 - 51 x cos (-57 + 2 pi t/24) - 25 x sin (63 + 2 pi t/12) (p < 0.0001). Ventricular arrhythmia occurrence rate was lowest between 2:00 and 3:00 A.M., and highest between 10:00 and 11:00 A.M. In addition, the same circadian pattern was demonstrated regardless of patient age, gender, left ventricular ejection fraction (< 35% or > or = 35%), and VT cycle length (< 300 or > or = 300 ms).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7762501     DOI: 10.1016/s0002-9149(99)80746-2

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  3 in total

1.  Influence of the Circadian System on Disease Severity.

Authors:  Mikhail Litinski; Frank Ajl Scheer; Steven A Shea
Journal:  Sleep Med Clin       Date:  2009-06-01

2.  Unexpected deviation in circadian variation of ventricular arrhythmias: the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial).

Authors:  Kristen K Patton; Anne S Hellkamp; Kerry L Lee; Daniel B Mark; George W Johnson; Jill Anderson; Gust H Bardy; Jeanne E Poole
Journal:  J Am Coll Cardiol       Date:  2014-04-16       Impact factor: 24.094

3.  Determinants of the daily rhythm of blood fluidity.

Authors:  Tatsushi Kimura; Tsutomu Inamizu; Kiyokazu Sekikawa; Masayuki Kakehashi; Kiyoshi Onari
Journal:  J Circadian Rhythms       Date:  2009-06-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.