Literature DB >> 7761583

Dose homogeneity in boron neutron capture therapy using an epithermal neutron beam.

M W Konijnenberg1, L G Dewit, B J Mijnheer, C P Raaijmakers, P R Watkins.   

Abstract

Simulation models based on the neutron and photon Monte Carlo code MCNP were used to study the therapeutic possibilities of the HB11 epithermal neutron beam at the High Flux Reactor in Petten. Irradiations were simulated in two types of phantoms filled with water or tissue-equivalent material for benchmark treatment planning calculations. In a cuboid phantom the influence of different field sizes on the thermal-neutron-induced dose distribution was investigated. Various shapes of collimators were studied to test their efficacy in optimizing the thermal-neutron distribution over a planning target volume and healthy tissues. Using circular collimators of 8, 12 and 15 cm diameter it was shown that with the 15-cm field a relatively larger volume within 85% of the maximum neutron-induced dose was obtained than with the 8- or 12-cm-diameter field. However, even for this large field the maximum diameter of this volume was 7.5 cm. In an ellipsoid head phantom the neutron-induced dose was calculated assuming the skull to contain 10 ppm 10B, the brain 5 ppm 10B and the tumor 30 ppm 10B. It was found that with a single 15-cm-diameter circular beam a very inhomogenous dose distribution in a typical target volume was obtained. Applying two equally weighted opposing 15-cm-diameter fields, however, a dose homogeneity within +/- 10% in this planning target volume was obtained. The dose in the surrounding healthy brain tissue is 30% at maximum of the dose in the center of the target volume. Contrary to the situation for the 8-cm field, combining four fields of 15 cm diameter gave no large improvement of the dose homogeneity over the target volume or a lower maximum dose in the healthy brain. Dose-volume histograms were evaluated for the planning target volume as well as for the healthy brain to compare different irradiation techniques, yielding a graphical confirmation of the above conclusions. Therapy with BNCT on brain tumors must be performed either with an 8-cm four-field irradiation or with two opposing 15- or 12-cm fields to obtain an optimal dose distribution.

Entities:  

Mesh:

Year:  1995        PMID: 7761583

Source DB:  PubMed          Journal:  Radiat Res        ISSN: 0033-7587            Impact factor:   2.841


  1 in total

1.  A comparison of dose distributions in gross tumor volume between boron neutron capture therapy alone and combined boron neutron capture therapy plus intensity modulation radiation therapy for head and neck cancer.

Authors:  Jia-Cheng Lee; Keh-Shih Chuang; Yen-Wan Hsueh Liu; Tzung-Yi Lin; Yi-Chiao Teng; Ling-Wei Wang
Journal:  PLoS One       Date:  2019-04-04       Impact factor: 3.240