Literature DB >> 7760703

Rotating frame RF current density imaging.

G C Scott1, M L Joy, R L Armstrong, R M Henkelman.   

Abstract

RF current density imaging (RF-CDI) is a new MRI technique for imaging the Larmor frequency current density parallel to B0 in electrolytic media. To extend the use of RF-CDI to biological tissue for generating conductivity contrast, the sensitivity must be increased and the data requirements reduced. A rotating frame approach, in which a large B1 field is applied simultaneously as a rotary echo with RF current, is proposed to meet these requirements. Rotating frame magnetic fields are encoded in the phase of an MRI image. Trials have now been performed with this sequence in a three-compartment cylindrical phantom containing doped water or mineral oil for detecting displacement, conduction and fringe field currents. In a postmortem rat study, 85.56 MHz RF currents injected by implanted electrodes created tissue dependent contrast because of the electrical properties of tissue. A sensitivity and artifact analysis was also performed. The sensitivity of this method is determined by the maximum RF pulse duration. SAR limits pose an upper bound on this time and B1, whereas the avoidance of phase artifacts imposes a lower bound on B1.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7760703     DOI: 10.1002/mrm.1910330309

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Magnetic resonance imaging of oscillating electrical currents.

Authors:  Nicholas W Halpern-Manners; Vikram S Bajaj; Thomas Z Teisseyre; Alexander Pines
Journal:  Proc Natl Acad Sci U S A       Date:  2010-04-26       Impact factor: 11.205

2.  Contrast-modified gradient echo imaging using rotary echo preparatory pulses.

Authors:  X P Zhu; P B Chilvers; C E Hutchinson; G A Morris; J M Hawnaur; J E Adams; C J Taylor
Journal:  MAGMA       Date:  1997-09       Impact factor: 2.310

3.  Magnetic resonance imaging of ionic currents in solution: the effect of magnetohydrodynamic flow.

Authors:  Mukund Balasubramanian; Robert V Mulkern; William M Wells; Padmavathi Sundaram; Darren B Orbach
Journal:  Magn Reson Med       Date:  2014-10-01       Impact factor: 4.668

4.  RF field visualization of RF ablation at the Larmor frequency.

Authors:  Kim Shultz; Pascal Stang; Adam Kerr; John Pauly; Greig Scott
Journal:  IEEE Trans Med Imaging       Date:  2011-07-18       Impact factor: 10.048

Review 5.  Recent progress and future challenges in MR electric properties tomography.

Authors:  Ulrich Katscher; Dong-Hyun Kim; Jin Keun Seo
Journal:  Comput Math Methods Med       Date:  2013-03-07       Impact factor: 2.238

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.