Literature DB >> 7760700

Changes in T2*-weighted images during hyperoxia differentiate tumors from normal tissue.

J N River, M Z Lewis, L M Lubich, G S Karczmar.   

Abstract

Experiments were performed to determine whether changes in T2*-weighted MR images during and after hyperoxia differentiate tumors from normal tissue. Mammary adenocarcinomas implanted in the right hind limbs of rats were studied. Gradient echo images were obtained at 2 Tesla with an evolution time of 20 ms and a recycle time of 1 s. Breathing gas was either air or 100% O2. Significant increases in image intensity were observed in tumor centers and rims during hyperoxia while much smaller changes were detected in the surrounding muscle. The relaxation rate (1/T2*) in tumors decreased during hyperoxia by an average of 2.5 +/- 1.0 s-1, while in muscle the average change was an increase of 0.6 +/- 2.1 s-1. The largest decreases in relaxation rate were detected in non-necrotic tumor regions with relatively low density of blood vessels. Immediately following hyperoxia significant decreases in intensity were detected in tumors while much smaller decreases were detected in the surrounding muscle.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7760700     DOI: 10.1002/mrm.1910330306

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

Review 1.  The optimal use of contrast agents at high field MRI.

Authors:  Siegfried Trattnig; Kathia Pinker; Ahmed Ba-Ssalamah; Iris-Melanie Nöbauer-Huhmann
Journal:  Eur Radiol       Date:  2006-03-01       Impact factor: 5.315

Review 2.  Magnetic resonance spectroscopy and imaging methods for measuring tumour and tissue oxygenation.

Authors:  C L McCoy; D J McIntyre; S P Robinson; E O Aboagye; J R Griffiths
Journal:  Br J Cancer Suppl       Date:  1996-07

3.  Analysing the response in R2* relaxation rate of intracranial tumours to hyperoxic and hypercapnic respiratory challenges: initial results.

Authors:  A Müller; S Remmele; I Wenningmann; H Clusmann; F Träber; S Flacke; R König; J Gieseke; W A Willinek; H H Schild; P Mürtz
Journal:  Eur Radiol       Date:  2010-09-22       Impact factor: 5.315

4.  Application of an exogenous hyperoxic contrast agent in MR mammography: initial results.

Authors:  Dorothee R Fischer; Jürgen R Reichenbach; Alexander Rauscher; Jan Sedlacik; Werner A Kaiser
Journal:  Eur Radiol       Date:  2004-09-22       Impact factor: 5.315

5.  New vanadium-based magnetic resonance imaging probes: clinical potential for early detection of cancer.

Authors:  Devkumar Mustafi; Bo Peng; Sean Foxley; Marvin W Makinen; Gregory S Karczmar; Marta Zamora; John Ejnik; Heather Martin
Journal:  J Biol Inorg Chem       Date:  2009-07-02       Impact factor: 3.358

6.  [Use of contrast agent in high-field MRI (3 T)].

Authors:  S Trattnig; A Ba-Ssalamah; I M Nöbauer-Huhmann; M Barth; K Pinker; V Mlynarik
Journal:  Radiologe       Date:  2004-01       Impact factor: 0.635

7.  Using R2* values to evaluate brain tumours on magnetic resonance imaging: preliminary results.

Authors:  Zhenghua Liu; Haibo Liao; Jianhua Yin; Yanfang Li
Journal:  Eur Radiol       Date:  2013-11-26       Impact factor: 5.315

8.  Preservation of tumour oxygen after hyperbaric oxygenation monitored by magnetic resonance imaging.

Authors:  Y Kinoshita; K Kohshi; N Kunugita; T Tosaki; A Yokota
Journal:  Br J Cancer       Date:  2000-01       Impact factor: 7.640

9.  Assessment of vascular reactivity in rat brain glioma by measuring regional blood volume during graded hypoxic hypoxia.

Authors:  C Julien; J-F Payen; I Troprès; R Farion; E Grillon; O Montigon; C Rémy
Journal:  Br J Cancer       Date:  2004-07-19       Impact factor: 7.640

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.