OBJECTIVES: This study sought to determine whether dobutamine stress echocardiography could accurately identify coronary artery disease after heart transplantation.
BACKGROUND: After heart transplantation, coronary artery disease is related to either diffuse concentric intimal thickening or focal stenosis and may be underdiagnosed by coronary angiography.
METHODS: We enrolled 41 patients, a mean (+/- SD) of 40 +/- 20 months after heart transplantation, at the time of their routine control coronary angiogram. Three patients were excluded because of poor echogenicity on the angiogram and one because of ventricular premature beats. Standard echocardiographic views were acquired at baseline and at incremental dobutamine infusion levels (from 5 to a maximal dose of 40 micrograms/kg body weight per min at 3-min intervals). Regional wall motion score was calculated from a 16-segment model, and each segment was graded from 1 (normal) to 4 (dyskinesia). Coronary angiography was performed 24 h after dobutamine stress echocardiography, and angiograms were analyzed in blinded manner.
RESULTS: Twenty-three (62%) of 37 patients had normal coronary angiographic findings. Dobutamine stress echocardiography showed abnormalities in only 2 of 23 patients. Fourteen patients (38%) had abnormal angiographic findings, seven of whom had stenoses > 50%. Dobutamine stress echocardiography correctly identified the corresponding hypoperfused segments in these seven patients. More of interest were the other seven patients, of whom three had angiographic nonsignificant stenoses (< 50%), and four had minor diffuse coronary irregularities. Dobutamine stress echocardiography showed hypokinesia in five of these seven patients despite nonsignificant lesions at coronary angiography. The respective overall sensitivity and specificity of dobutamine stress echocardiography were 86% and 91%. At follow-up, 2 of the 37 patients had an acute myocardial infarction. Both had abnormal findings on dobutamine stress echocardiography: One had normal coronary angiographic results, and one had significant coronary lesions.
CONCLUSIONS: Dobutamine stress echocardiography is a useful technique for the diagnosis of coronary artery disease after heart transplantation. These preliminary results indicate that dobutamine stress echocardiography may have a predictive value for further ischemic events in heart transplant recipients.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7759721     DOI: 10.1016/0735-1097(95)00084-h

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  9 in total

1.  Diagnostic and prognostic value of myocardial perfusion gated SPECT in orthotopic heart transplant recipients.

Authors:  Alain Manrique; Mathieu Bernard; Anne Hitzel; Michael Bubenheim; Christophe Tron; Denis Agostini; Alain Cribier; Pierre Véra; Jean Paul Bessou; Michel Redonnet
Journal:  J Nucl Cardiol       Date:  2010-02-12       Impact factor: 5.952

2.  New developments for the detection and treatment of cardiac vasculopathy.

Authors:  Kevin J Clerkin; Ziad A Ali; Donna M Mancini
Journal:  Curr Opin Cardiol       Date:  2017-02-15       Impact factor: 2.161

Review 3.  How to Approach the Assessment of Cardiac Allograft Vasculopathy in the Modern Era: Review of Invasive Imaging Modalities.

Authors:  Ali Javaheri; Naveen Saha; Scott M Lilly
Journal:  Curr Heart Fail Rep       Date:  2016-04

4.  Position Statement on Indications of Echocardiography in Adults - 2019.

Authors:  Silvio Henrique Barberato; Minna Moreira Dias Romano; Adenalva Lima de Souza Beck; Ana Clara Tude Rodrigues; André Luiz Cerqueira de Almeida; Bruna Morhy Borges Leal Assunção; Eliza de Almeida Gripp; Fabio Villaça Guimarães Filho; Henry Abensur; José Maria Del Castillo; Marcelo Haertel Miglioranza; Marcelo Luiz Campos Vieira; Márcio Vinicius Lins de Barros; Maria do Carmo Pereira Nunes; Maria Estefania Bosco Otto; Renato de Aguiar Hortegal; Rodrigo Bellio de Mattos Barretto; Thais Harada Campos; Vicente Nicoliello de Siqueira; Samira Saady Morhy
Journal:  Arq Bras Cardiol       Date:  2019-08-08       Impact factor: 2.000

Review 5.  Multi-modal imaging of the pediatric heart transplant recipient.

Authors:  Jonathan H Soslow; Margaret M Samyn
Journal:  Transl Pediatr       Date:  2019-10

6.  Stress echocardiography for the diagnosis of coronary artery disease: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2010-06-01

7.  Evolving concepts and treatment strategies for cardiac allograft vasculopathy.

Authors:  Rodolfo Denadai Benatti; David O Taylor
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-01

8.  Dobutamine stress echocardiography after cardiac transplantation: implications of donor-recipient age difference.

Authors:  Patrick H Gibson; Fernando Riesgo; Jonathan B Choy; Daniel H Kim; Harald Becher
Journal:  Echo Res Pract       Date:  2015-05-11

Review 9.  Usefulness and limitations of transthoracic echocardiography in heart transplantation recipients.

Authors:  Sergio Mondillo; Massimo Maccherini; Maurizio Galderisi
Journal:  Cardiovasc Ultrasound       Date:  2008-01-11       Impact factor: 2.062

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.