Literature DB >> 7759694

Atherosclerosis in angiographically "normal" coronary artery reference segments: an intravascular ultrasound study with clinical correlations.

G S Mintz1, J A Painter, A D Pichard, K M Kent, L F Satler, J J Popma, Y C Chuang, T A Bucher, L E Sokolowicz, M B Leon.   

Abstract

OBJECTIVES: This study evaluated the magnitude, patterns and clinical correlates of atherosclerosis in angiographically "normal" reference segments in patients undergoing transcatheter therapy for symptomatic coronary artery disease.
BACKGROUND: Pathologic studies indicate that the extent of coronary atherosclerosis is underestimated by visual analysis of angiographically normal coronary artery segments. Intravascular ultrasound allows detailed, high quality cross-sectional imaging of the coronary arteries in vivo.
METHODS: Intravascular ultrasound was used to study angiographically normal coronary artery reference segments in 884 patients evaluated for transcatheter therapy for symptomatic native coronary artery disease. The reference segment was the most visually normal intravascular ultrasound cross section within 10 mm proximal to the target lesion but distal to any major side branch. Results are presented as mean value +/- 1 SD.
RESULTS: Only 60 (6.8%) of 884 angiographically normal reference segments were normal by intravascular ultrasound. Reference segment percent cross-sectional narrowing measured 51 +/- 13% and correlated poorly with the target lesion percent cross-sectional narrowing (r = 0.166, p < 0.0001). Reference segments contained less calcific and dense fibrotic plaque and proportionately more soft plaque elements. Independent predictors of reference segment percent cross-sectional narrowing were male gender, patient age, diabetes mellitus, hypercholesterolemia and presence of multivessel disease. Independent predictors of reference segment calcification were patient age and serum creatinine levels. Reference segment percent cross-sectional narrowing in 723 patients undergoing transcatheter therapy was similar to that in patients studied for diagnostic purposes; however, reference segment arc of calcium was greater in treated patients (43 +/- 81 vs. 25 +/- 57, p = 0.015). Reference segment disease was not an independent predictor of subsequent angiographic restenosis or clinical events within 12 months of follow-up.
CONCLUSIONS: Atherosclerosis is ubiquitous in angiographically normal coronary artery reference segments. Reference segment disease parallels the severity of target lesion disease and is associated with many of the conventional risk factors for coronary artery disease. Because of its sensitivity in detecting atherosclerosis in angiographically normal reference segments, intravascular ultrasound should enhance the study of risk factors for atherosclerosis and the results of therapies to control disease progression.

Entities:  

Mesh:

Year:  1995        PMID: 7759694     DOI: 10.1016/0735-1097(95)00088-l

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  81 in total

Review 1.  Myocardial infarction in patients with normal coronary arteries: proposed pathogenesis and predisposing risk factors.

Authors:  S P Pinney; L E Rabbani
Journal:  J Thromb Thrombolysis       Date:  2001-02       Impact factor: 2.300

Review 2.  Understanding coronary artery disease: tomographic imaging with intravascular ultrasound.

Authors:  Paul Schoenhagen; Steven Nissen
Journal:  Heart       Date:  2002-07       Impact factor: 5.994

3.  Validation of an automated system for luminal and medial-adventitial border detection in three-dimensional intravascular ultrasound.

Authors:  Jon D Klingensmith; E Murat Tuzcu; Steven E Nissen; D Geoffrey Vince
Journal:  Int J Cardiovasc Imaging       Date:  2003-04       Impact factor: 2.357

4.  Finding the age of the patient's heart.

Authors:  D Vijay Anand; David Lipkin; Avijit Lahiri
Journal:  BMJ       Date:  2003-05-17

5.  ECG-gated multislice spiral computed tomography to clarify lesion severity in a case of left main stenosis. Multislice spiral computed tomography to clarify lesion severity.

Authors:  Ralf Koos; Andreas Horst Mahnken; Anil-Martin Sinha; Joachim Ernst Wildberger; Rainer Hoffmann
Journal:  Int J Cardiovasc Imaging       Date:  2003-08       Impact factor: 2.357

Review 6.  Optimum guidance of complex PCI by coronary pressure measurement.

Authors:  Nico H J Pijls
Journal:  Heart       Date:  2004-09       Impact factor: 5.994

7.  The maximum necrotic core area is most often located proximally to the site of most severe narrowing: a virtual histology intravascular ultrasound study.

Authors:  Michiel A de Graaf; Joella E van Velzen; Fleur R de Graaf; Joanne D Schuijf; Jouke Dijkstra; Jeroen J Bax; Johan H C Reiber; Martin J Schalij; Ernst E van der Wall; J Wouter Jukema
Journal:  Heart Vessels       Date:  2012-02-18       Impact factor: 2.037

8.  Angiographic patterns of in-stent restenosis classified by computed tomography in patients with drug-eluting stents: correlation with invasive coronary angiography.

Authors:  Jingwei Pan; Zhigang Lu; Jiayin Zhang; Minghua Li; Meng Wei
Journal:  Eur Radiol       Date:  2012-07-08       Impact factor: 5.315

9.  Atherosclerosis imaging with intravascular ultrasound. Validating acquisition and measurement tools to assure meaningful results.

Authors:  Paul Schoenhagen
Journal:  Int J Cardiovasc Imaging       Date:  2006-10       Impact factor: 2.357

10.  Coronary plaque quantification by voxel analysis: dual-source MDCT angiography versus intravascular sonography.

Authors:  Harald Brodoefel; Christof Burgstahler; Adeel Sabir; Chun-Shan Yam; Faisal Khosa; Claus D Claussen; Melvin E Clouse
Journal:  AJR Am J Roentgenol       Date:  2009-03       Impact factor: 3.959

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.