Comparative study of four glass ionomer luting cements during post pull-out tests.

C A Mitchell1, J F Orr, K N Connor, J P Magill, G R Maguire.   

Abstract

OBJECTIVES: The aim of this study was to compare the maximum loads and modes of failure of four glass ionomer luting cements during post pull-out tests.
METHODS: The cements studied included two based on conventional glass ionomer cement chemistry, i.e., a hand-mixed cement and an encapsulated cement, and two based on the newer light-cured chemistry, i.e., a restorative cement used at a low powder:liquid ratio and an experimental luting cement. One hundred and forty bovine incisors were cut 13 mm from the apex and prepared with post channels, 1.75 mm in diameter and 9 mm long. Ni-Cr-Mb bonding alloy posts were cast and sandblasted prior to cementation into the roots with each of the cements. Twenty-four hours later, pull-out tests were carried out at a strain rate of 0.5 mm/min. The maximum loads and modes of failure were noted. The data obtained were analyzed using a Kruskal-Wallis test followed by comparison of groups using Mann-Whitney tests.
RESULTS: Comparison of the maximum loads revealed a significant difference between the conventional encapsulated cement and all other cements. Weibull analysis of the results gave values for the Weibull moduli and probabilities of survival for a post under a given load for each cement and indicated that the newer cements performed better than the conventional cements. SIGNIFICANCE: Further research into the in vitro and in vivo behavior of the resin-modified glass ionomer cements in clinical situations where light-curing is not possible is justified.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7758854     DOI: 10.1016/0109-5641(94)90046-9

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  3 in total

1.  Push-Out Bond Strength of Endodontic Posts Cemented to Extracted Teeth: An In-Vitro Evaluation.

Authors:  Syed Rashid Habib; Abdul Sadekh Ansari; Aleshba Saba Khan; Nawaf M Alamro; Meshari A Alzaaqi; Yazeed A Alkhunefer; Abdulaziz A AlHelal; Talal M Alnassar; Abdulaziz S Alqahtani
Journal:  Materials (Basel)       Date:  2022-09-30       Impact factor: 3.748

2.  Analysis of bond strength by pull out test on fiber glass posts cemented in different lengths.

Authors:  Mariana Benedetti Ferreira Webber; Silvia Masae de Araújo Michida; Fabiano Carlos Marson; Giovani Corrêa de Oliveira; Cleverson de Oliveira E Silva
Journal:  J Int Oral Health       Date:  2015-04

3.  Effect of different luting cements on fracture resistance in endodontically treated teeth.

Authors:  Narmin Mohammadi; Amir Ahmad Ajami; Soodabeh Kimyai; Mojdeh Rezaei Aval
Journal:  Iran Endod J       Date:  2008-10-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.