Literature DB >> 7756000

Findings of automatic border detection in subjects with left ventricular diastolic dysfunction by Doppler echocardiography.

S Gottlieb1, A Keren, Z Khoury, S Stern.   

Abstract

Left ventricular automatic border detection (ABD) patterns were defined in the parasternal short-axis and the apical four-chamber views and were compared with pulsed-wave diastolic Doppler flow-velocity patterns of the mitral valve in 49 subjects (aged 39 to 87 years), 10 selected normal individuals, and 39 consecutive patients with high-quality echocardiographic Doppler studies and relaxation abnormalities (Doppler peak early diastolic velocity/peak late velocity ratio < 1). Both short-axis and apical four-chamber views were useful in the assessment of diastolic function by ABD. However, in subjects with high-quality two-dimensional echocardiographic Doppler studies, ABD was technically more feasible in the apical four-chamber view (97%; 38/39 subjects) than in the short-axis view (64%; 25/39 subjects) and correlated better with Doppler parameters. Compared with normal subjects, patients with abnormal Doppler relaxation patterns showed significant differences in diastolic filling indexes obtained by the ABD technique. The ratio of peak rapid filling rate/peak atrial filling rate (PRFR/PAFR) obtained from the dA/dt waveform in the apical four-chamber view had the highest correlation with Doppler indexes (r = 0.79). A PRFR/PAFR ratio of 1.5 best discriminated between normal individuals and subjects with relaxation abnormalities, with high sensitivity and specificity (95% and 100%, respectively). The PRFR/PAFR ratio obtained from the dA/dt waveform seemed to be a simple and useful method to distinguish between normal and abnormal left ventricular diastolic filling, as defined by Doppler echocardiography.

Entities:  

Mesh:

Year:  1995        PMID: 7756000     DOI: 10.1016/s0894-7317(05)80404-3

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  3 in total

1.  Analysis of cardiac left-ventricular volume based on time warping averaging.

Authors:  E G Caiani; A Porta; G Baselli; M Turiel; S Muzzupappa; M Pagani; A Malliani; S Cerutti
Journal:  Med Biol Eng Comput       Date:  2002-03       Impact factor: 2.602

2.  Detection and monitoring of cardiotoxicity-what does modern cardiology offer?

Authors:  Ruxandra Jurcut; Hans Wildiers; Javier Ganame; Jan D'hooge; Robert Paridaens; Jens-Uwe Voigt
Journal:  Support Care Cancer       Date:  2008-01-16       Impact factor: 3.603

3.  Murine left atrium and left atrial appendage structure and function: echocardiographic and morphologic evaluation.

Authors:  Francesca Colazzo; Laura Castiglioni; Luigi Sironi; Lucia Fontana; Elena Nobili; Matteo Franzosi; Uliano Guerrini
Journal:  PLoS One       Date:  2015-04-30       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.