Literature DB >> 7754576

In vivo comparison of 3D ultrasonography and magnetic resonance imaging in volume estimation of human kidneys.

O H Gilja1, A I Smievoll, N Thune, K Matre, T Hausken, S Odegaard, A Berstad.   

Abstract

The objective of this study was to evaluate the accuracy of a three-dimensional ultrasound system (3D-US) compared with Magnetic Resonance Imaging (MRI) in volume estimation of human kidneys in vivo. Twenty healthy volunteers were scanned fasting in supine position with MRI and with a 3D-US. An ultrasound sector scanner with a mechanical transducer coupled to a tilting motor provided images of multiple sections of kidneys. A 3.25-MHz transducer was tilted through 88 degrees yielding 81 frames, and volume estimation was performed on a Unix workstation after manual contour indication. Data acquisition with MRI was performed by using a 1-T magnet. Eighteen included kidneys [mean +/- standard deviation (SD)] measured 155.7 +/- 26.4 mL (range 110.0-205.0 mL) by 3D ultrasound and 171.8 +/- 24.6 mL (range 127.5-211.0 mL) by MRI, yielding a good correlation (r = 0.82, p < 0.001) between the two methods. The mean difference was -16.1 +/- 15.6 mL (SD) and the limits of agreement were -49.0 mL. We conclude that this 3D-US is accurate in volume estimation of human kidneys in vivo.

Entities:  

Mesh:

Year:  1995        PMID: 7754576     DOI: 10.1016/0301-5629(94)00082-4

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  16 in total

1.  Three dimensional echocardiography documents haemodynamic improvement by biventricular pacing in patients with severe heart failure.

Authors:  W Y Kim; P Søgaard; P T Mortensen; H K Jensen; A K Pedersen; B O Kristensen ; H Egeblad
Journal:  Heart       Date:  2001-05       Impact factor: 5.994

2.  Gastric emptying measured by ultrasonography.

Authors:  Odd Helge Gilja; Trygve Hausken; Svein degaard; Arnold Berstad
Journal:  World J Gastroenterol       Date:  1999-04       Impact factor: 5.742

3.  Relationships between gastric accommodation and gastrointestinal sensations in healthy volunteers. A study using the barostat technique and two- and three-dimensional ultrasonography.

Authors:  M W Mundt; T Hausken; A J P M Smout; M Samsom
Journal:  Dig Dis Sci       Date:  2005-09       Impact factor: 3.199

Review 4.  Gastric accommodation assessed by ultrasonography.

Authors:  Odd Helge Gilja; Johan Lunding; Trygve Hausken; Hans Gregersen
Journal:  World J Gastroenterol       Date:  2006-05-14       Impact factor: 5.742

5.  Fundal dysaccommodation in functional dyspepsia: head-to-head comparison between the barostat and three-dimensional ultrasonographic technique.

Authors:  M W Mundt; M Samsom
Journal:  Gut       Date:  2006-01-26       Impact factor: 23.059

6.  Three-dimensional ultrasound reconstruction of the pelvicaliceal system: an in-vitro study.

Authors:  Khurshid R Ghani; James Pilcher; Uday Patel; David Rowland; Daruish Nassiri; Ken Anson
Journal:  World J Urol       Date:  2008-06-07       Impact factor: 4.226

7.  Are renal volumes measured by magnetic resonance imaging and three-dimensional ultrasound in the term neonate comparable?

Authors:  Alison L Kent; Rajeev Jyoti; Cameron Robertson; Lisa Gonsalves; Sandra Meskell; Bruce Shadbolt; Michael C Falk
Journal:  Pediatr Nephrol       Date:  2010-05       Impact factor: 3.714

8.  Relationship of renal morphology on 3-dimensional ultrasonography with renal pathologic findings and outcome in biopsy-proven nephropathy.

Authors:  Jianwei Xu; Sung Il Hwang; Hak Jong Lee; Ho Jun Chin
Journal:  Exp Ther Med       Date:  2017-12-13       Impact factor: 2.447

9.  Feasibility and application of 3-dimensional ultrasound for measurement of gastric volumes in healthy adults and adolescents.

Authors:  Mhd Louai Manini; Duane D Burton; Duane D Meixner; Deborah J Eckert; Matthew Callstrom; Grant Schmit; Mounif El-Youssef; Michael Camilleri
Journal:  J Pediatr Gastroenterol Nutr       Date:  2009-03       Impact factor: 2.839

Review 10.  Advanced imaging and visualization in gastrointestinal disorders.

Authors:  Odd Helge Gilja; Jan G Hatlebakk; Svein Odegaard; Arnold Berstad; Ivan Viola; Christopher Giertsen; Trygve Hausken; Hans Gregersen
Journal:  World J Gastroenterol       Date:  2007-03-07       Impact factor: 5.742

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.