Literature DB >> 7754015

Fine-needle aspiration biopsy versus fine-needle capillary (nonaspiration) biopsy: in vivo comparison.

C A Savage1, K D Hopper, C S Abendroth, J S Hartzel, T R TenHave.   

Abstract

PURPOSE: To evaluate, in vivo, the efficacy of fine-needle capillary (nonaspiration) biopsy (FNCB) versus fine-needle aspiration biopsy (FNAB) when performed at the same site with a coaxial technique.
MATERIALS AND METHODS: In 91 patients, biopsy was performed at 140 sites in 93 lesions mostly throughout the chest and abdomen with either FNCB or FNAB, or both (98 sites). A coaxial technique with a 22-gauge needle was used. The quality of the specimen was graded by a blinded pathologist, who also made a pathologic diagnosis.
RESULTS: No statistically significant difference was noted in the graded criteria performance plus diagnostic yield between the two techniques. When performed before FNAB, FNCB yielded a better quality specimen of a particular site. However, there was no difference in the graded quality of FNAB whether performed before or after FNCB. Insufficient specimens were obtained at 30 (21.4%) of 140 sites with FNCB versus only 18 (12.8%) with FNAB.
CONCLUSION: FNCB is an alternative to FNAB and provides a cellular diagnostic specimen from most lesions. When a coaxial method is used and both techniques are employed, the diagnostic accuracy of these techniques is 84%.

Entities:  

Mesh:

Year:  1995        PMID: 7754015     DOI: 10.1148/radiology.195.3.7754015

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  4 in total

1.  Syringe and needle size, syringe type, vacuum generation, and needle control in aspiration procedures.

Authors:  Luke J Haseler; Randy R Sibbitt; Wilmer L Sibbitt; Adrian A Michael; Charles M Gasparovic; Arthur D Bankhurst
Journal:  Cardiovasc Intervent Radiol       Date:  2010-11-06       Impact factor: 2.740

2.  Image-directed fine-needle aspiration biopsy of the thyroid with safety-engineered devices.

Authors:  Randy R Sibbitt; Dennis J Palmer; Wilmer L Sibbitt; Arthur D Bankhurst
Journal:  Cardiovasc Intervent Radiol       Date:  2010-11-06       Impact factor: 2.740

3.  Should we apply suction during fine needle cytology of thyroid lesions? A prospective study of 200 cases.

Authors:  Amit Kumar Chowhan; K V Sreedhar Babu; Alok Sachan; N Rukmangdha; Rashmi Patnayak; K Radhika; B V Phaneendra; M Kumaraswamy Reddy
Journal:  J Clin Diagn Res       Date:  2014-10-20

4.  Safety of percutaneous ultrasound-guided fine-needle aspiration of adrenal lesions in dogs: Perception of the procedure by radiologists and presentation of 50 cases.

Authors:  Pascaline Pey; Alessia Diana; Federica Rossi; Jeremy Mortier; Ulrike Kafka; Stefanie Veraa; Anna Groth; Megan MacLellan; Chiara Marin; Federico Fracassi
Journal:  J Vet Intern Med       Date:  2020-03-11       Impact factor: 3.333

  4 in total