Literature DB >> 7744943

The acute vascular response to intramedullary reaming. Microsphere estimation of blood flow in the intact ovine tibia.

I L Reichert1, I D McCarthy, S P Hughes.   

Abstract

The tibial nutrient artery supplies 62% of cortical blood flow in the diaphysis and normal blood flow is centrifugal (Willans 1987). Intramedullary reaming destroys the nutrient artery and injures the endosteal surface of the cortex. Trueta (1974) suggested that the direction of blood flow can reverse from centrifugal to centripetal after loss of the endosteal supply. We examined this hypothesis by measuring cortical and periosteal blood flow after intramedullary reaming of the tibia in eight sheep, using 57Co radiolabelled microspheres. The unreamed contralateral tibiae served as a control group. Thirty minutes after reaming there was no significant change in cortical blood flow, but a sixfold increase in the periosteal flow. Our study confirms Trueta's hypothesis; after trauma or in other pathological states, flow can become centripetal.

Entities:  

Mesh:

Year:  1995        PMID: 7744943

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  16 in total

Review 1.  Skeletal Blood Flow in Bone Repair and Maintenance.

Authors:  Ryan E Tomlinson; Matthew J Silva
Journal:  Bone Res       Date:  2013-12-31       Impact factor: 13.567

2.  Tibial lengthening using a reamed type intramedullary nail and an Ilizarov external fixator.

Authors:  Hayoung Kim; Sang Ki Lee; Kap Jung Kim; Jae Hoon Ahn; Won Sik Choy; Yong In Kim; Jea Yun Koo
Journal:  Int Orthop       Date:  2008-04-16       Impact factor: 3.075

3.  Tibial lengthening over an intramedullary nail in patients with short stature or leg-length discrepancy: a comparative study.

Authors:  Qianchen Guo; Tao Zhang; Yongfa Zheng; Shiqing Feng; Xinlong Ma; Feng Zhao
Journal:  Int Orthop       Date:  2011-06-07       Impact factor: 3.075

4.  In brief: closed tibial shaft fractures.

Authors:  P Maxwell Courtney; Joseph Bernstein; Jaimo Ahn
Journal:  Clin Orthop Relat Res       Date:  2011-09-20       Impact factor: 4.176

5.  Reamed intramedullary exchange nailing in the operative treatment of aseptic tibial shaft nonunion.

Authors:  Christian Hierholzer; Jan Friederichs; Claudio Glowalla; Alexander Woltmann; Volker Bühren; Christian von Rüden
Journal:  Int Orthop       Date:  2016-10-28       Impact factor: 3.075

6.  Statistical atlas-based morphological variation analysis of the asian humerus: towards consistent allometric implant positioning.

Authors:  K Wu; K L Wong; S J K Ng; S T Quek; B Zhou; D P Murphy; Z J Daruwalla; H Ren
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-06-13       Impact factor: 2.924

7.  Distraction osteogenesis technique using an intramedullary nail and a monolateral external fixator in the reconstruction of massive postosteomyelitis skeletal defects of the femur.

Authors:  Zhihong Li; Xiangsheng Zhang; Liqun Duan; Xiaoming Chen
Journal:  Can J Surg       Date:  2009-04       Impact factor: 2.089

8.  Current concepts of leg lengthening.

Authors:  Carol C Hasler; Andreas H Krieg
Journal:  J Child Orthop       Date:  2012-03-21       Impact factor: 1.548

9.  Quantification of Reaming Debris at the Fracture Gap of Diaphyseal A2 and A3 Fractures After Reamed Intramedullary Nailing of the Sheep Tibia.

Authors:  Florian Hoegel; Ahmed Abdulazim; Peter Augat; Volker Buehren
Journal:  Eur J Trauma Emerg Surg       Date:  2008-03-07       Impact factor: 3.693

10.  Reamed interlocking intramedullary nailing for the treatment of tibial diaphyseal fractures and aseptic nonunions. Can we expect an optimum result?

Authors:  Byron E Chalidis; George E Petsatodis; Nick C Sachinis; Christos G Dimitriou; Anastasios G Christodoulou
Journal:  Strategies Trauma Limb Reconstr       Date:  2009-08-25
View more