Serial defibrillation threshold measures in man: a prospective controlled study.

J E Poole1, G H Bardy, G L Dolack, P J Kudenchuk, J Anderson, G Johnson.   

Abstract

UNLABELLED: Serial DFT Measures in Man.
INTRODUCTION: The defibrillation threshold (DFT) may change throughout the first year following implantation of a cardioverter defibrillator, but it remains uncertain if changes are a consequence of changes in clinical condition or are related to fundamental alterations at the electrode-tissue interface. The purpose of this study was to evaluate the extent and time course of DFT changes over the first year following implantable cardioverter defibrillator (ICD) surgery when extraneous clinical and device variables potentially affecting the DFT were excluded. METHODS AND
RESULTS: We prospectively enrolled 61 patients undergoing epicardial or nonthoracotomy/transvenous ICD therapy into a series of follow-up studies where the DFT was measured at implant and at 1, 6, 12, and 52 weeks following implantation in a uniform manner. Stored energy DFT was measured and recorded for all patients. Patient exclusion criteria were: (1) inability to complete all five measures of the DFT; (2) institution of Class I or Class III antiarrhythmic drugs at any time during the study; (3) lead system changes (relocation or new leads) or programming changes in pulse width or current pathway; or (4) development of a significant change in their clinical status, such as decompensated congestive heart failure or acute ischemia. Only 20 of the 61 patients satisfied the criteria required to complete the study. Two of the excluded patients developed high DFTs, which required reprogramming of the current pathway. Eight patients had an epicardial lead system, and 12 had a nonthoracotomy lead system.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7743005     DOI: 10.1111/j.1540-8167.1995.tb00753.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  3 in total

1.  Early postoperative rise in defibrillation threshold associated with hematoma formation with unipolar defibrillation system.

Authors:  D Y Yazmajian; D Schwartzman; D J Callans; C D Gottieb; F E Marchlinski
Journal:  J Interv Card Electrophysiol       Date:  1997-09       Impact factor: 1.900

Review 2.  The Saga of Defibrillation Testing: When Less Is More.

Authors:  Marye J Gleva; Melissa Robinson; Jeanne Poole
Journal:  Curr Cardiol Rep       Date:  2018-05-05       Impact factor: 2.931

3.  [Influence of waveform and configuration of electrodes on the defibrillation threshold of implantable cardioverter-defibrillators].

Authors:  M Block; D Hammel; G Breithardt
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.