Literature DB >> 7741642

The vicious cycle of nonhealing neointima in fabric vascular prostheses.

Y Noishiki1, Y Tomizawa, Y Yamane, A Matsumoto.   

Abstract

Delayed neointimal healing of a fabric vascular prosthesis was investigated in an animal study focusing on the relationship between red thrombus, fibrinolysis, and endothelialization on the luminal surface. Fabric vascular prostheses were implanted into the descending aortas of 72 dogs. Fifty-nine grafts were explanted from 1 h to 1,705 days after implantation. One hour after implantation, the graft wall was red in color due to fresh thrombus; however, at 1 day the luminal surface became white. Red thrombus reappeared at 1 week and remained present in the long-term. Microscopically the initial red thrombus contained numerous erythrocytes. The white thrombus at 1 day was composed of a dense fibrin network without erythrocytes. At 2 days numerous lacunae appeared in the fibrin layer, and at 3-5 days cavernae and low density fibrin areas were present secondary to fibrinolysis. These areas allowed the blood components to infiltrate into the fibrin layer, and as a result red thrombus reformed within it. The thrombi on the luminal surface in the long-term was always red in color and composed of complicated, multiple stages of thrombus formation, i.e., fresh thrombus with erythrocytes, dense fibrin without erythrocytes, low fibrin density areas, lacunae and cavernae in the fibrin layer, and blood component infiltration into these spaces. Thrombus was always newly formed and present, and involuted in parallel due to fibrinolysis, suggesting that these phenomena perpetuated in a vicious cycle. However, at the anastomoses fibrinolysis was present, but blood component infiltration was prevented by the endothelial cell lining. These results suggest that endothelialization may arrest the vicious cycle of nonhealing neointima in fabric vascular prostheses.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7741642     DOI: 10.1111/j.1525-1594.1995.tb02238.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  4 in total

Review 1.  Atrial septum defect closure device in a beating heart, from the perspective of a researcher in artificial organs.

Authors:  Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2012-06-23       Impact factor: 1.731

2.  Characterization of surface modified polyester fabric.

Authors:  Roy Joseph; R Shelma; A Rajeev; C V Muraleedharan
Journal:  J Mater Sci Mater Med       Date:  2008-06-27       Impact factor: 3.896

3.  Evaluation of endothelial cell integrins after in \ vitro contact with polyethylene terephthalate.

Authors:  E Cenni; D Granchi; E Verri; G Remiddi; D Cavedagna; A Di Leo
Journal:  J Mater Sci Mater Med       Date:  2001-04       Impact factor: 3.896

4.  Tissue responses to stent grafts with endo-exo-skeleton for saccular abdominal aortic aneurysms in a canine model.

Authors:  Young Il Kim; Young Ho Choi; Jin Wook Chung; Hyo-Cheol Kim; Young Ho So; Hyun Beom Kim; Seung-Kee Min; Jae Hyung Park
Journal:  Korean J Radiol       Date:  2014-09-12       Impact factor: 3.500

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.