Literature DB >> 7739373

Lactate quantification by means of press spectroscopy--influence of refocusing pulses and timing scheme.

F Schick1, T Nägele, U Klose, O Lutz.   

Abstract

The quantitative assessment of lactic acid in tissue is an important goal for in vivo volume-selective NMR spectroscopy to aid in the noninvasive diagnosis of oxygen deficiency of other metabolic disorders. PRESS localized 1H spectra provide comparatively high signal-to-noise ratio from small volume elements in a single acquisition mode. The quantification of lactate after multipulse excitation is not trivial due to the J-coupling characteristics which do not occur for the substances serving as references. The influence of the timing scheme and of the quality of the refocusing pulses was systematically evaluated for the lactate resonances by volume-selective measurements. Gaussian pulses, Hanning-filtered sinc pulses, and numerically optimized RE-BURP-pulses were applied for refocusing the magnetization in the PRESS sequence and the effects on the lactate AX3 spin system were compared. For these pulses, sequence parameters are presented providing high sensitivity to lactate signals. Timing schemes are shown which provide good quantification of lactate, even in cases with B1-inhomogeneities or slight misadjustment of the transmitter amplitude. The combination of both echo times in the double-echo sequences clearly influences the signal characteristics of lactate at overall echo times near TE = 145 and 290 ms, which may result in pure in-phase magnetization for this weakly coupled homonuclear system. Numerically optimized refocusing pulses (RE-BURP) provided up to 50% higher signal ratio of the methyl protons of lactate to uncoupled nuclei than the often used Hanning-filtered sinc pulses.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7739373     DOI: 10.1016/0730-725x(94)00104-b

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  4 in total

1.  Pitfalls in lactate measurements at 3T.

Authors:  T Lange; U Dydak; T P L Roberts; H A Rowley; M Bjeljac; P Boesiger
Journal:  AJNR Am J Neuroradiol       Date:  2006-04       Impact factor: 3.825

2.  Metabolite concentrations and relaxation in perinatal cerebral hypoxic-ischemic injury.

Authors:  E B Cady
Journal:  Neurochem Res       Date:  1996-09       Impact factor: 3.996

3.  ISMRM workshop on fat-water separation: insights, applications and progress in MRI.

Authors:  Houchun Harry Hu; Peter Börnert; Diego Hernando; Peter Kellman; Jingfei Ma; Scott Reeder; Claude Sirlin
Journal:  Magn Reson Med       Date:  2012-06-12       Impact factor: 4.668

4.  Spectroscopic sampling of the left side of long-TE spin echoes: a free lunch?

Authors:  Robert V Mulkern; Mukund Balasubramanian
Journal:  MAGMA       Date:  2017-09-07       Impact factor: 2.310

  4 in total