Literature DB >> 7734653

Importance of ground section thickness for reliable histomorphometrical results.

C B Johansson1, P Morberg.   

Abstract

Ten screw-shaped commercially pure titanium implants were inserted in 10 rabbit tibia. The implants with surrounding bone were harvested after 12 weeks. The samples were processed to be cut and ground. Histomorphometrical analyses of the bone-to-metal contact and the bone area around the entire implants were performed on transvertically cut sections at intervals, starting with 100 microns thick sections; then the same sections were further ground down to 50, 30 and 10 microns. The thicker the section the more bone-to-metal contacts were demonstrated. A statistically significant difference was obtained when comparing the 100-30, 100-10, 50-30 and the 50-10 microns thick sections. Comparing the area measurements of 100-10, 50-30, 50-10 and 30-10 microns revealed a statistically significant difference. Bone-to-metal contact measurements on ground sections that are too thick (over 30 microns) may result in overestimations of the 'true' bony contacts.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7734653     DOI: 10.1016/0142-9612(95)98268-j

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  8 in total

1.  Histomorphometric estimation of age in paraffin-embedded ribs: a feasibility study.

Authors:  Catherine Cannet; José Pablo Baraybar; Maryelle Kolopp; Pierre Meyer; Bertrand Ludes
Journal:  Int J Legal Med       Date:  2010-04-06       Impact factor: 2.686

2.  Comparison of histomorphometrical data obtained with two different image analysis methods.

Authors:  Lucia Ballerini; Victoria Franke-Stenport; Gunilla Borgefors; Carina B Johansson
Journal:  J Mater Sci Mater Med       Date:  2007-03-27       Impact factor: 3.896

Review 3.  Resolving the CaP-bone interface: a review of discoveries with light and electron microscopy.

Authors:  Kathryn Grandfield; Anders Palmquist; Håkan Engqvist; Peter Thomsen
Journal:  Biomatter       Date:  2012 Jan-Mar

4.  Quantification of osseointegration of plasma-polymer coated titanium alloyed implants by means of microcomputed tomography versus histomorphometry.

Authors:  Carolin Gabler; Carmen Zietz; Richard Bieck; Rebecca Göhler; Tobias Lindner; Maximilian Haenle; Birgit Finke; Jürgen Meichsner; Holger Testrich; Mathias Nowottnick; Bernhard Frerich; Rainer Bader
Journal:  Biomed Res Int       Date:  2015-04-30       Impact factor: 3.411

5.  A correlative imaging based methodology for accurate quantitative assessment of bone formation in additive manufactured implants.

Authors:  Hua Geng; Naomi M Todd; Aine Devlin-Mullin; Gowsihan Poologasundarampillai; Taek Bo Kim; Kamel Madi; Sarah Cartmell; Christopher A Mitchell; Julian R Jones; Peter D Lee
Journal:  J Mater Sci Mater Med       Date:  2016-05-06       Impact factor: 3.896

Review 6.  A multiscale analytical approach to evaluate osseointegration.

Authors:  Anders Palmquist
Journal:  J Mater Sci Mater Med       Date:  2018-05-07       Impact factor: 3.896

7.  The effect of housing environment on bone healing in a critical radius defect in New Zealand White rabbits.

Authors:  Patricia Hedenqvist; Amela Trbakovic; Torbjörn Mellgren; Caroline Öhman-Mägi; Petra Hammarström Johansson; Elin Manell; Stina Ekman; Cecilia Ley; Marianne Jensen-Waern; Andreas Thor
Journal:  PLoS One       Date:  2020-05-21       Impact factor: 3.240

8.  Aseptic Ligatures Induce Marginal Peri-Implant Bone Loss-An 8-Week Trial in Rabbits.

Authors:  David Reinedahl; Silvia Galli; Tomas Albrektsson; Pentti Tengvall; Carina B Johansson; Petra Hammarström Johansson; Ann Wennerberg
Journal:  J Clin Med       Date:  2019-08-18       Impact factor: 4.241

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.