Literature DB >> 7732972

Regional and arterial localization of radioactive microparticles after local delivery by unsupported or supported porous balloon catheters.

R L Wilensky1, K L March, I Gradus-Pizlo, D Schauwecker, M B Michaels, J Robinson, K Carlson, D R Hathaway.   

Abstract

Catheter-mediated intramural delivery of pharmaceutical agents after angioplasty is a potential method to reduce postangioplasty restenosis. The efficacy of such delivery has been limited both by an incomplete initial intramural deposition of delivered agents and by rapid diffusion of soluble agents from the site of delivery. The local delivery of microparticulate agents results in prolonged retention of material at the delivery site. Accordingly this study was designed to evaluate the complementary issue of the initial delivery efficiency and pattern of localization of microparticles after local catheter-mediated delivery with two types of porous balloons. These two types were a "standard" porous balloon (PB) in which hydraulic pressure both inflated the balloon and infused the agents and a porous balloon with a mechanical undergirding that permitted mechanical expansion (PB/ME) before agent infusion. Radioactive cerium 141-labeled microparticles (11.4 microns diameter) were locally delivered into atherosclerotic rabbit femoral arteries after angioplasty to test the hypothesis that use of the PB/ME apparatus would yield enhanced intramural particle deposition and decreased systemic administration by increased balloon-wall contact before microparticle infusion. Six animals underwent infusion with the PB catheter, and seven animals underwent infusion with the PB/ME catheter. An image of the in vivo particle distribution was obtained with a gamma camera during infusion, immediately after infusion, and 1, 3, and 7 days after infusion. Tissue samples from the artery, periadventitia, thigh, calf, and foot musculature, and liver were obtained at animal death, and retained radioactivity was measured with a well counter.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7732972     DOI: 10.1016/0002-8703(95)90103-5

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  6 in total

Review 1.  Retractable-needle catheters: an update on local drug delivery in coronary interventions.

Authors:  Paolo Angelini; Wijay Bandula
Journal:  Tex Heart Inst J       Date:  2008

2.  Adventitia as a target for intravascular local drug delivery.

Authors:  T Y Huehns; P Gonschior; B Höfling
Journal:  Heart       Date:  1996-06       Impact factor: 5.994

Review 3.  Drug-Eluting Balloons and Drug-Eluting Stents in the Treatment of Peripheral Vascular Disease.

Authors:  Jonathan Lindquist; Kristofer Schramm
Journal:  Semin Intervent Radiol       Date:  2019-02-05       Impact factor: 1.513

Review 4.  Nanotechnology in interventional cardiology.

Authors:  Tillmann Cyrus; Samuel A Wickline; Gregory M Lanza
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2011-07-11

5.  Deposition of nanoparticles in the arterial vessel by porous balloon catheters: localization by confocal laser scanning microscopy and transmission electron microscopy.

Authors:  Ulrich Westedt; Lucian Barbu-Tudoran; Andreas K Schaper; Marc Kalinowski; Heiko Alfke; Thomas Kissel
Journal:  AAPS PharmSci       Date:  2002

6.  Modified paclitaxel-loaded nanoparticles for inhibition of hyperplasia in a rabbit arterial balloon injury model.

Authors:  Lin Mei; Hongfan Sun; Xu Jin; Dunwan Zhu; Rui Sun; Minfang Zhang; Cunxian Song
Journal:  Pharm Res       Date:  2007-03-20       Impact factor: 4.580