Effect of respiration on Doppler parameters of normal tricuspid porcine bioprosthetic valves.

B Cosyns1, G van Camp, A Friart, J L Vandenbossche.   

Abstract

The Doppler indexes of tricuspid porcine bioprosthetic valves were evaluated in twelve patients without clinical and two-dimensional echocardiographic evidence of valve dysfunction. Peak and mean pressure gradients across the prostheses were measured using the simplified Bernoulli equation. All the Doppler measurements were compared during inspiration and expiration. During inspiration peak velocity, peak gradient and mean gradient (1.52 +/- 0.28 m/s; 9.7 +/- 3.05 mmHg; 4.07 +/- 1.16 mmHg) were significantly higher than during expiration (1.28 +/- 0.8 m/s; 6.58 +/- 2.7 mmHg; 2.98 +/- 1.13 mmHg; p < 0.01) but pressure half time was not significantly different (122 +/- 62 ms versus 134 +/- 75 ms; p > 0.05). Inspiratory range of peak velocities, peak gradients, mean gradients and pressure half times were respectively 0.8-2.04 m/s; 4.9-16.6 mmHg; 1.2-7.2 mmHg; 42-340 ms while expiratory range of values was 0.8-1.93 m/s; 2.6-15 mmHg; 1.1-5.7 mmHg; 46-345 ms. These data suggest that even very long pressure half times do not indicate valve dysfunction. This study demonstrates that large variation of Doppler parameters are present during respiration and could produce inaccuracy in the assessment of bioprostheses in tricuspid position if they are not taken in consideration.

Entities:  

Mesh:

Year:  1995        PMID: 7730682     DOI: 10.1007/bf01148954

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  11 in total

1.  Pulmonary blood flow and venous return during spontaneous respiration.

Authors:  G A BRECHER; C A HUBAY
Journal:  Circ Res       Date:  1955-03       Impact factor: 17.367

2.  Doppler assessment of right ventricular filling in a normal population. Comparison with left ventricular filling dynamics.

Authors:  W A Zoghbi; G B Habib; M A Quinones
Journal:  Circulation       Date:  1990-10       Impact factor: 29.690

3.  Doppler echocardiographic findings in normal-functioning St. Jude Medical and Björk-Shiley mechanical prostheses in the tricuspid valve position.

Authors:  V Martí; F Carreras; X Borrás; G Pons-Lladó
Journal:  Am J Cardiol       Date:  1991-02-01       Impact factor: 2.778

4.  Doppler echocardiographic characteristics of normal and dysfunctioning prosthetic valves in the tricuspid and mitral position.

Authors:  M Pye; N Weerasana; W H Bain; I Hutton; S M Cobbe
Journal:  Br Heart J       Date:  1990-01

5.  Normal and abnormal prosthetic valve function as assessed by Doppler echocardiography.

Authors:  I P Panidis; J Ross; G S Mintz
Journal:  J Am Coll Cardiol       Date:  1986-08       Impact factor: 24.094

6.  Tricuspid stenosis in prosthetic valve endocarditis. Diagnosis by Doppler echocardiography.

Authors:  J F Lewis; R L Peniston; O S Randall; J Spencer; L M Sheller
Journal:  Chest       Date:  1987-02       Impact factor: 9.410

7.  Usefulness of Doppler echocardiography in detecting tricuspid valve stenosis.

Authors:  J E Pérez; P A Ludbrook; G G Ahumada
Journal:  Am J Cardiol       Date:  1985-02-15       Impact factor: 2.778

8.  Non-invasive diagnosis and assessment of tricuspid regurgitation and stenosis using one and two dimensional echo-pulsed Doppler.

Authors:  C Veyrat; D Kalmanson; M Farjon; J P Manin; G Abitbol
Journal:  Br Heart J       Date:  1982-06

9.  Effect of respiration on venous return and stroke volume in cardiac tamponade. Mechanism of pulsus parodoxus.

Authors:  W G Guntheroth; B C Morgan; G L Mullins
Journal:  Circ Res       Date:  1967-04       Impact factor: 17.367

10.  Effect of respiration on echocardiographic ventricular dimensions and relationship to the second heart sound.

Authors:  B S Lewis; N Lewis; M S Gotsman
Journal:  Eur J Cardiol       Date:  1979-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.