Literature DB >> 7728834

Electrical conductance and electrode area on sound smooth enamel in extracted teeth.

M C Huysmans1, E H Verdonschot, P Rondel.   

Abstract

Electrical conductance measurements are being used experimentally to diagnose caries. Current equipment, e.g. the electronic caries monitor (ECM), uses a probe to scan occlusal fissures. For full-mouth examination this method is rather time-consuming. A method with which only one measurement is needed for an entire (occlusal) surface would be preferable. However, the enlargement of the area being measured will influence the conductance. It was the purpose of this study to investigate the relationship between the electrical conductance of human teeth and the enamel electrode area, and to compare the range of results of surface measurements with those of the scanning method. Twenty-five sound extracted teeth were selected for the study. The reference electrode of the ECM was connected to the roots. The buccal surface was blotted dry, and a coloured dentifrice was syringed in increments onto the surface. After each increment the surface was photographed together with a metric reference, a conductance measurement was performed by holding the ECM probe tip in the dentifrice, and the ECM reading was recorded. For each tooth between 5 and 10 increments were applied and measured. The photographs were digitised and the electrode areas were calculated. A least squares curve fitting procedure yielded a linear relationship between conductance and electrode area (0.88 < or = R2 < or = 1.0, mean R2 = 0.97). For most teeth the threshold for dentinal caries as used for scanning ECM measurements (ECM reading = 6.00) was reached only when the electrode area exceeded 12 mm2. For 6 teeth this conductance was already reached between 5 and 12 mm2.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7728834     DOI: 10.1159/000262047

Source DB:  PubMed          Journal:  Caries Res        ISSN: 0008-6568            Impact factor:   4.056


  3 in total

1.  Age-related changes in ac-impedance spectroscopy studies of normal human dentine.

Authors:  Aziza H Eldarrat; David J Wood; Girish M Kale; Alec S High
Journal:  J Mater Sci Mater Med       Date:  2007-02-03       Impact factor: 4.727

2.  Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition.

Authors:  Naghmeh Gharizadeh; Azita Kaviani; Samaneh Nik
Journal:  Dent Res J (Isfahan)       Date:  2010

Review 3.  Detecting Short-Term Changes in the Activity of Caries Lesions with the Aid of New Technologies.

Authors:  M H van der Veen
Journal:  Curr Oral Health Rep       Date:  2015
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.