Literature DB >> 7727006

Arthroscopic Bankart repair with the Suretac device. Part II: Experimental observations.

J J Warner1, M D Miller, P Marks.   

Abstract

Arthroscopic Bankart repair using the Suretac device (Acufex Microsurgical, Mansfield, MA) was developed as an alternative to both the staple and suture repair techniques. While offering some technical advantages compared with these other approaches, it's technical limitations and pitfalls have only been described anecdotally based on the clinical experience of several surgeons. The purpose of this study was to define these limitations and pitfalls. Eight cadaver shoulders underwent arthroscopic Bankart repair using the Suretac device after first arthroscopically creating a Bankart lesion. These shoulders were then dissected to reveal the placement of the Suretacs and the adequacy of the Bankart lesion repair. Glenoids were transected in the transverse plane and embedded in clear methylmethacrylate to show placement of the Suretac device relative to the articular surface. There were several technical errors that occurred: (1) Inadequate abrasion of the anterior and inferior juxta-articular scapular neck; (2) inadequate superior and medial shift of the inferior glenohumeral ligament before placement of the lowest Suretac, (3) medial placement of the Suretac relative to the articular margin; and (4) insufficient capture and compression of capsular tissue by the Suretac device. This procedure is technically difficult and careful attention must be paid to each step of preparation and repair. Recognition of the common errors may help the surgeon to avoid these pitfalls in the clinical situation.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7727006     DOI: 10.1016/0749-8063(95)90083-7

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  3 in total

1.  History of shoulder instability surgery.

Authors:  Pietro Randelli; Davide Cucchi; Usman Butt
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-19       Impact factor: 4.342

2.  In vivo healing after capsular plication in an ovine shoulder model.

Authors:  B T Kelly; A S Turner; M Bansal; M Terry; B R Wolf; R F Warren; D W Altchek; A A Allen
Journal:  Iowa Orthop J       Date:  2005

3.  [Open Bankart shoulder stabilization using bioabsorbable staples. Technique and results].

Authors:  F Reuther; G Möckel
Journal:  Unfallchirurg       Date:  2004-02       Impact factor: 1.000

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.