Literature DB >> 7726443

The incidence of gastroesophageal reflux with the laryngeal mask: a comparison with the face mask using esophageal lumen pH electrodes.

T M Owens1, P Robertson, C Twomey, M Doyle, N McDonald, A J McShane.   

Abstract

To test the hypothesis that the laryngeal mask airway (LMA) predisposes patients to gastroesophageal reflux, we randomly assigned 55 patients having elective surgery to receive standardized anesthesia with the LMA or with conventional face mask (FM) plus airway. A pH-sensitive probe with two electrodes, 10 cm apart, was passed nasally into the esophagus 1 h before induction of anesthesia, and recordings were made continuously until 30 min after surgery. At the distal electrode, 30 cm from the anterior nares, there was a significant difference in the incidence of reflux: 53.6% with the LMA versus 22.2% with the FM (P < 0.05). At the level of the proximal electrode, 20 cm from the anterior nares, there was no difference between groups. Multiple reflux events, defined as two or more reflux events before, during, or after anesthesia, were significantly more frequent in the LMA group (P < 0.05). Reflux events continued in the postanesthesia care unit (PACU) in both groups with no significant difference between groups. There was no clinical evidence of aspiration of gastric contents in either group. Use of the LMA appears to result in increased reflux to the level of the mid to upper esophagus, and is associated with a more frequent incidence of multiple reflux events than use of the FM.

Entities:  

Mesh:

Year:  1995        PMID: 7726443     DOI: 10.1097/00000539-199505000-00022

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  5 in total

Review 1.  [Laryngeal masks. Possibilities and limits].

Authors:  H Hillebrand; J Motsch
Journal:  Anaesthesist       Date:  2007-06       Impact factor: 1.041

2.  The 1998 European Resuscitation Council guidelines for adult advanced life support. Advanced Life Support Working Group of the European Resuscitation Council.

Authors: 
Journal:  BMJ       Date:  1998-06-20

3.  Lightwand: a useful aid in faciomaxillary trauma.

Authors:  Shruti Jain; Umesh Bhadani
Journal:  J Anesth       Date:  2011-01-20       Impact factor: 2.078

Review 4.  Comparison between supraglottic airway devices and endotracheal tubes in patients undergoing laparoscopic surgery: A systematic review and meta-analysis.

Authors:  Sun Kyung Park; Geum Ko; Geun Joo Choi; Eun Jin Ahn; Hyun Kang
Journal:  Medicine (Baltimore)       Date:  2016-08       Impact factor: 1.889

5.  Extraglottic airway devices: A review.

Authors:  Ramesh Ramaiah; Debasmita Das; Sanjay M Bhananker; Aaron M Joffe
Journal:  Int J Crit Illn Inj Sci       Date:  2014-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.