Literature DB >> 7723650

Accumulated oxygen deficit during supramaximal all-out and constant intensity exercise.

P B Gastin1, D L Costill, D L Lawson, K Krzeminski, G K McConell.   

Abstract

Two studies were conducted to test the validity of an all-out procedure for the assessment of the maximal accumulated oxygen deficit (AOD). Subjects in study 1 (N = 9; VO2max = 57 +/- 3 ml.kg-1.min-1 [+/- SEM]) completed three supramaximal efforts on a cycle ergometer. Exhaustive exercise during an all-out isokinetic procedure (mean intensity of 149% VO2max) was compared with constant intensity exercise at approximately 110% and 125% VO2max. Subjects in study 2 (N = 12; VO2max = 55 +/- 3 ml.kg-1.min-1) completed a constant intensity test to exhaustion at approximately 110% VO2max and a 90 s all-out test on a Monark friction loaded cycle ergometer (mean intensity of 143% VO2max). The AOD within each study were not significantly different (study 1:43.9, 44.1, and 42.0 ml.kg-1 for the 110%, 125%, and all-out tests; study 2: 52.1 and 51.2 ml.kg-1 for the 110% and all-out tests, respectively; P > 0.05). The total amount of work was significantly greater the longer the test, the additional work being attributed to aerobic processes. The rate of both aerobic and anaerobic energy production in the first 30 s of exercise was directly related to exercise intensity and the protocol used. The results indicate that an all-out procedure provides a valid estimate of the maximal AOD and shows potential for a more complete assessment of anaerobic ability as traditional indices of high intensity exercise performance are also obtained.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7723650

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  12 in total

Review 1.  Warm up I: potential mechanisms and the effects of passive warm up on exercise performance.

Authors:  David Bishop
Journal:  Sports Med       Date:  2003       Impact factor: 11.136

2.  Validity of the two-parameter model in estimating the anaerobic work capacity.

Authors:  J Dekerle; G Brickley; A J P Hammond; J S M Pringle; H Carter
Journal:  Eur J Appl Physiol       Date:  2005-11-01       Impact factor: 3.078

Review 3.  The maximal accumulated oxygen deficit method: a valid and reliable measure of anaerobic capacity?

Authors:  Dionne A Noordhof; Jos J de Koning; Carl Foster
Journal:  Sports Med       Date:  2010-04-01       Impact factor: 11.136

4.  Variable resistance all-out test to generate accumulated oxygen deficit and predict anaerobic capacity.

Authors:  P B Gastin; D L Lawson
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1994

5.  Influence of training status on maximal accumulated oxygen deficit during all-out cycle exercise.

Authors:  P B Gastin; D L Lawson
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1994

Review 6.  Energy system interaction and relative contribution during maximal exercise.

Authors:  P B Gastin
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

7.  The effects of elevated levels of sodium bicarbonate (NaHCO₃) on the acute power output and time to fatigue of maximally stimulated mouse soleus and EDL muscles.

Authors:  M F Higgins; J Tallis; M J Price; R S James
Journal:  Eur J Appl Physiol       Date:  2012-12-01       Impact factor: 3.078

8.  Oxygen uptake and blood metabolic responses to a 400-m run.

Authors:  Christine Hanon; Pierre-Marie Lepretre; David Bishop; Claire Thomas
Journal:  Eur J Appl Physiol       Date:  2010-01-09       Impact factor: 3.078

9.  Effects of Acute Supramaximal Cycle Exercise on Plasma FFA Concentration in Obese Adolescent Boys.

Authors:  Georges Jabbour; Horia-Daniel Iancu; Anne Paulin; Jean-Marc Lavoie; Sophie Lemoine-Morel; Hassane Zouhal
Journal:  PLoS One       Date:  2015-06-15       Impact factor: 3.240

10.  Effects of High-Intensity Training on Anaerobic and Aerobic Contributions to Total Energy Release During Repeated Supramaximal Exercise in Obese Adults.

Authors:  Georges Jabbour; Horia-Daniel Iancu; Anne Paulin
Journal:  Sports Med Open       Date:  2015-10-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.