Abstract

Eighty-four patients (121 eyes) with high myopia who had cataract surgery and intraocular lens implantation completed a survey on preferred postoperative refraction. Forty-two percent of the sample reported that they were accustomed to removing their glasses to read a newspaper or book. These respondents were fitted with soft contact lenses and their refraction changed to 0 D, -3.00 D, and -5.00 D. Of the patients whose best corrected postoperative visual acuity was 20/40 or better (n = 63), 48% preferred the -3.00 D correction; 38%, the 0 D correction; and 14%, -5.00 D. Of those with a best corrected postoperative visual acuity worse than 20/200 (n = 8), 80% preferred the -5.00 D refraction, which allowed them to read close up. Most patients with phakic eyes and good visual acuity (n = 13) preferred the 0 D and -3.00 D corrections. Our results indicate that in patients with high myopia, it is important to take patient preference into account when selecting postoperative refraction.

Entities:  

Mesh:

Year:  1995        PMID: 7722896     DOI: 10.1016/s0886-3350(13)80476-2

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

Review 1.  Management of cataract surgery in a high myope.

Authors:  H Seward; R Packard; D Allen
Journal:  Br J Ophthalmol       Date:  2001-11       Impact factor: 4.638

2.  Binocular visual function of myopic pseudophakic monovision.

Authors:  Ken Hayashi; Motoaki Yoshida; Hiroshi Sasaki; Akira Hirata
Journal:  Jpn J Ophthalmol       Date:  2018-02-20       Impact factor: 2.447

3.  Evaluation of refractive error after cataract surgery in highly myopic eyes.

Authors:  Tae Yokoi; Muka Moriyama; Kengo Hayashi; Noriaki Shimada; Kyoko Ohno-Matsui
Journal:  Int Ophthalmol       Date:  2013-01-12       Impact factor: 2.031

4.  Accuracy of Intraocular Lens Power Calculation Formulas in Myopic Eyes with Target Refractions of Emmetropia and Intentional Myopia.

Authors:  Daiki Sakai; Yasuhiko Hirami; Makoto Nakamura; Yasuo Kurimoto
Journal:  Clin Ophthalmol       Date:  2021-11-27

5.  Investigating target refraction advice provided to cataract surgery patients by UK optometrists and ophthalmologists.

Authors:  Emily Charlesworth; Alison J Alderson; Fiona Fylan; Richard A Armstrong; Aman Chandra; David B Elliott
Journal:  Ophthalmic Physiol Opt       Date:  2022-02-18       Impact factor: 3.992