Literature DB >> 7722267

Percutaneous Kirschner wire fixation through the snuff box: an anatomic study.

B D Steinberg1, K D Plancher, R S Idler.   

Abstract

We undertook this study to better define the anatomy of the radial aspect of the wrist and to establish a zone of safety for the placement of Kirschner wires, cannulated screws, and arthroscopes within the anatomic snuff box. Twenty fresh frozen cadaver upper extremities underwent placement of three percutaneous Kirschner wires under fluoroscopic guidance through the anatomic snuff box. In each extremity, one Kirschner wire was placed into the radial styloid, one across the scaphocapitate joint, and one across the scapholunate joint. A safe zone of mean 0.68 sq cm was found deep to the subcutaneous tissue bordered by the radial styloid, the first dorsal compartment, the radial artery, and the superficial radial nerve. Kirschner wires placed distal, dorsal, or palmar to the borders of the safe zone were at great risk of injuring neurovascular structures. To minimize the risk of injury to adjacent structures, we advise a limited incision in the safe zone with blunt dissection to the wrist capsule. Though improved anatomic understanding, we established a new location for the arthroscopic 1,2 portal within the snuff box.

Entities:  

Mesh:

Year:  1995        PMID: 7722267     DOI: 10.1016/S0363-5023(05)80059-0

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  13 in total

1.  Anatomical survey of terminal branching patterns of superficial branch of radial nerve in fetuses.

Authors:  Richa Gupta; Anjali Aggarwal; Daisy Sahni; K Harjeet; Manisha Barnwal
Journal:  Surg Radiol Anat       Date:  2012-01-24       Impact factor: 1.246

2.  Reliable techniques to avoid damaging the superficial radial nerve due to percutaneous Kirschner wire fixation of the distal radius fracture through the radial styloid process.

Authors:  Yixin Chen; Xin Zheng; Junfei Wang; Yawen Zhu; Chaoshuang Zhan
Journal:  Surg Radiol Anat       Date:  2010-03-21       Impact factor: 1.246

3.  Echography-Guided Pinning for Prevention of Iatrogenic Injuries to the Radial Nerve during Fixation of Extra-articular Distal Radius Fracture: An Anatomical Study.

Authors:  Jérémie Bouillis; Stéphanie Lallouet; Mickaël Ropars
Journal:  J Wrist Surg       Date:  2017-03-08

4.  Is there a safe zone to avoid superficial radial nerve injury with Kirschner wire fixation in the treatment of distal radius? A cadaveric study.

Authors:  Ayman M Ali; Barakat El-Alfy; Hamdino Attia
Journal:  J Clin Orthop Trauma       Date:  2014-08-29

5.  The Safety of the Thenar Portal: An Anatomical Study of the Thumb Carpometacarpal Arthroscopy.

Authors:  Yong-Wei Pan; Leung-Kim Hung
Journal:  J Wrist Surg       Date:  2016-12-26

6.  Ultrasonographic findings of superficial radial nerve and cephalic vein.

Authors:  Ki Hoon Kim; Eun Jin Byun; Eun Hyun Oh
Journal:  Ann Rehabil Med       Date:  2014-02-25

7.  An Anatomical Study to Demonstrate the Proximity of Kirschner Wires to Structures at Risk in Percutaneous Pinning of Distal Radius Fractures.

Authors:  John A Santoshi; Prashant N Chaware; Abhijit P Pakhare; Bertha A D Rathinam
Journal:  J Hand Microsurg       Date:  2015-05-01

8.  Preserving the superficial branch of the radial nerve during carpometacarpal and metacarpophalangeal joint arthroscopy: an anatomical study.

Authors:  Mickaël Ropars; Isabelle Fontaine; Xavier Morandi; Eric Berton; Rajiv Kaila; Pierre Darnault
Journal:  Surg Radiol Anat       Date:  2010-01-16       Impact factor: 1.246

9.  Anatomic characteristics and clinical importance of the superficial branch of the radial nerve.

Authors:  Z Ash Aktan Ikiz; H Uçerler
Journal:  Surg Radiol Anat       Date:  2004-12       Impact factor: 1.246

Review 10.  Extensor tendon injury to the index and middle finger secondary to Kirschner wire insertion for a distal radial fracture.

Authors:  Sayyied Jamshead Kirmani; Shaheel Bhuva; William Lo; Ajeet Kumar
Journal:  Ann R Coll Surg Engl       Date:  2008-03       Impact factor: 1.891

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.