Literature DB >> 7720793

Light maxillary expansion forces with the magnetic expansion device. A preliminary investigation.

M A Darendeliler1, C Strahm, J P Joho.   

Abstract

An active maxillary magnetic expansion device (MED) was developed to be used clinically. The aim was to show the effects of light and continuous forces producing less traumatic stimulation of maxillary sutural growth than a conventional rapid maxillary expansion device. In this study, two different types of appliances were used on six patients between 7 years 4 months and 16 years 2 months: the first type was bonded, the other one used bands. For better appreciation, four implants were placed on each patient: two apically between central and lateral incisors, and two between second premolars and molars. A standardized radiographic technique was used to take occlusal radiographs, and postero-anterior and lateral headplates. The results varied according to the age and the appliance used. The skeletal effect with the banded MED was between 16 and 77 per cent, and for the bonded MED 0 and 25 per cent in comparison to the overall expansion. It seems that 250-500 g of continuous magnetic forces can produce dental and skeletal movements in a light force expansion concept, but further studies with larger samples are needed to make firm conclusions.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7720793     DOI: 10.1093/ejo/16.6.479

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  5 in total

1.  Maxillary expansion in an animal model with light, continuous force.

Authors:  Achint Utreja; Carol Bain; Brett Turek; Robert Holland; Rawan AlRasheed; Parand Sorkhdini; W Eugene Roberts
Journal:  Angle Orthod       Date:  2018-01-24       Impact factor: 2.079

2.  Review of maxillary expansion appliance activation methods: engineering and clinical perspectives.

Authors:  D L Romanyk; M O Lagravere; R W Toogood; P W Major; J P Carey
Journal:  J Dent Biomech       Date:  2010-06-28

3.  Effects of a novel magnetic orthopedic appliance (MOA-III) on the dentofacial complex in mild to moderate skeletal class III children.

Authors:  Ning Zhao; Jing Feng; Zheng Hu; Rongjing Chen; Gang Shen
Journal:  Head Face Med       Date:  2015-10-14       Impact factor: 2.151

4.  Maxillary expansion with the memory screw: a preliminary investigation.

Authors:  Koray Halicioğlu; Ali Kiki; Ibrahim Yavuz
Journal:  Korean J Orthod       Date:  2012-04-27       Impact factor: 1.372

5.  3D digital analysis of tooth movement with magnets and elastics in vitro.

Authors:  Yoshiki Ishida; Yukinori Kuwajima; Kaho Ogawa; Cliff Lee; John Da Silva; Jacob Emge; Shigemi Ishikawa-Nagai
Journal:  Heliyon       Date:  2021-07-10
  5 in total