Literature DB >> 7719602

Near infra-red spectroscopy: a non-invasive monitor of perfusion and oxygenation within the microcirculation of limbs and flaps.

M S Irwin1, M S Thorniley, C J Doré, C J Green.   

Abstract

Reliable early detection of adverse circulatory changes within a flap following free tissue transfer and early re-exploration are vital to minimise flap failure. Most surgeons rely on clinical assessment to monitor these changes but techniques such as plethysmography and laser Doppler have their advocates. These methods are limited however to measuring changes close to the surface. Near infra-red spectroscopy (NIRS) is a relatively new, non-invasive technique which allows continuous monitoring of concentration changes in oxy-, deoxy- and total haemoglobin (HbO2, Hb and HbT), as well as oxidised cytochrome aa3, through tissue up to 10 cm in depth. Information is provided on tissue oxygen supply, cellular oxygen utilisation, blood volume and perfusion status. A study has been performed in 10 rabbit hind limbs to assess the ability of NIRS to detect and distinguish between venous, arterial and total vascular occlusion. Clear patterns of change have been identified which allow rapid detection of vascular occlusion with accurate prediction of site. Arterial occlusions were characterised by an increase in Hb with a corresponding decrease in HbO2 and HbT. Venous occlusions resulted in an increase in HbT with relatively minor fluctuations in Hb and HbO2. Simultaneous occlusion of both artery and vein produced similar changes to those of arterial occlusion except that HbT decreased only minimally. These findings suggest that NIRS has a potentially useful role in the monitoring of free flaps, with the great advantage that perfusion can be measured to a considerable depth and information provided on the oxygenation profiles both accurately and non-invasively.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7719602     DOI: 10.1016/0007-1226(95)90024-1

Source DB:  PubMed          Journal:  Br J Plast Surg        ISSN: 0007-1226


  17 in total

1.  Insight in human skin microcirculation using in vivo reflectance-mode confocal laser scanning microscopy.

Authors:  Mehmet Ali Altintas; A A Altintas; M Guggenheim; A E Steiert; M C Aust; A D Niederbichler; C Herold; P M Vogt
Journal:  J Digit Imaging       Date:  2009-06-10       Impact factor: 4.056

2.  A System for Simple Real-Time Anastomotic Failure Detection and Wireless Blood Flow Monitoring in the Lower Limbs.

Authors:  Michael A Rothfuss; Nicholas G Franconi; Jignesh V Unadkat; Michael L Gimbel; Alexander Star; Marlin H Mickle; Ervin Sejdic
Journal:  IEEE J Transl Eng Health Med       Date:  2016-08-25       Impact factor: 3.316

3.  Postoperative quantitative assessment of reconstructive tissue status in a cutaneous flap model using spatial frequency domain imaging.

Authors:  Amr Yafi; Thomas S Vetter; Thomas Scholz; Sarin Patel; Rolf B Saager; David J Cuccia; Gregory R Evans; Anthony J Durkin
Journal:  Plast Reconstr Surg       Date:  2011-01       Impact factor: 4.730

4.  Early detection of complete vascular occlusion in a pedicle flap model using quantitative [corrected] spectral imaging.

Authors:  Michael R Pharaon; Thomas Scholz; Scott Bogdanoff; David Cuccia; Anthony J Durkin; David B Hoyt; Gregory R D Evans
Journal:  Plast Reconstr Surg       Date:  2010-12       Impact factor: 4.730

5.  Measurements of tissue viability in transplantation.

Authors:  M S Thorniley; S Simpkin; E Balogun; K Khaw; C Shurey; K Burton; C J Green
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1997-06-29       Impact factor: 6.237

6.  Nature and mechanism of peripheral nerve damage in an experimental model of non-freezing cold injury.

Authors:  M S Irwin
Journal:  Ann R Coll Surg Engl       Date:  1996-07       Impact factor: 1.891

7.  Breath-Hold Paradigm to Assess Variations in Oxygen Flow in Diabetic Foot Ulcers Using a Noncontact Near-Infrared Optical Scanner.

Authors:  Kevin Leiva; Jagadeesh Mahadevan; Kacie Kaile; Richard Schutzman; Edwin Robledo; Sivakumar Narayanan; Varalakshmi Muthukrishnan; Viswanathan Mohan; Wensong Wu; Anuradha Godavarty
Journal:  Adv Wound Care (New Rochelle)       Date:  2019-07-25       Impact factor: 4.730

Review 8.  Flap Monitoring Using Transcutaneous Oxygen or Carbon Dioxide Measurements.

Authors:  Sameer H Halani; Austin S Hembd; Xingchen Li; Ben Kirby; Courtney C Beard; Nicholas T Haddock; Thomas M Suszynski
Journal:  J Hand Microsurg       Date:  2020-11-16

9.  Quantitative assessment of partial vascular occlusions in a swine pedicle flap model using spatial frequency domain imaging.

Authors:  Adrien Ponticorvo; Eren Taydas; Amaan Mazhar; Thomas Scholz; Hak-Su Kim; Jonathan Rimler; Gregory R D Evans; David J Cuccia; Anthony J Durkin
Journal:  Biomed Opt Express       Date:  2013-01-18       Impact factor: 3.732

10.  Tissue hemoglobin index: a non-invasive optical measure of total tissue hemoglobin.

Authors:  Dean Myers; Michelle McGraw; Mark George; Kristine Mulier; Greg Beilman
Journal:  Crit Care       Date:  2009-11-30       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.