High speed cine-radiographic study of aortic valve leaflet motion.

M J Thubrikar1, J L Heckman, S P Nolan.   

Abstract

The leaflets of the aortic valve move extremely rapidly during opening and closing. To analyse this movement, radiopaque markers were placed on the aortic valves of four dogs during cardiopulmonary bypass. One to five months later the dogs were studied using x-ray, and the marker motion was recorded on cine-film at 500 frames/second. Simultaneous aortic pressure varied from 70/30 to 188/152 mmHg and heart rate from 33 to 150 bpm. Analysis of 19 systolic periods and 2500 cine-frames indicated that leaflet motion occurred in four phases: 1--rapid movement during initial opening, 2--a little movement near maximal excursion, 3--a slow movement during early closing and 4--a rapid movement to complete closure. Phases 1 and 4 averaged 17.6 and 16.5 msec respectively, and were independent of heart rate, whereas the length of phases 2 and 3 varied with heart rate. The leaflets moved 82% of their maximum excursion during rapid opening and 53% during rapid closure. Leaflet curvature reversed in both the radial and the circumferential directions during opening. The leaflet profile in the radial direction changed as follows: during rapid opening, the belly of the leaflet moved outward, first causing the leaflet to straighten and then to conform to the profile of blood flow. During closure the belly of the leaflet moved centrally, causing the leaflet to curve toward the ventricle. The leaflet profile in the circumferential direction indicated that during opening the midpoint of the leaflet leads the motion towards the aortic wall.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 7719506

Source DB:  PubMed          Journal:  J Heart Valve Dis        ISSN: 0966-8519


  6 in total

1.  Viscoelastic properties of the aortic valve interstitial cell.

Authors:  W David Merryman; Paul D Bieniek; Farshid Guilak; Michael S Sacks
Journal:  J Biomech Eng       Date:  2009-04       Impact factor: 2.097

Review 2.  Biomechanical Behavior of Bioprosthetic Heart Valve Heterograft Tissues: Characterization, Simulation, and Performance.

Authors:  Joao S Soares; Kristen R Feaver; Will Zhang; David Kamensky; Ankush Aggarwal; Michael S Sacks
Journal:  Cardiovasc Eng Technol       Date:  2016-08-09       Impact factor: 2.495

Review 3.  On the biomechanics of heart valve function.

Authors:  Michael S Sacks; W David Merryman; David E Schmidt
Journal:  J Biomech       Date:  2009-06-21       Impact factor: 2.712

Review 4.  Aortic valve: mechanical environment and mechanobiology.

Authors:  Sivakkumar Arjunon; Swetha Rathan; Hanjoong Jo; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2013-03-21       Impact factor: 3.934

5.  Aortic valve opening and closure: the clover dynamics.

Authors:  Emmanuel Lansac; Hou-Sen Lim; Yu Shomura; Khee Hiang Lim; Nolan T Rice; Isabelle Di Centa; Pouya Youssefi; Wolfgang Goetz; Carlos M G Duran
Journal:  Ann Cardiothorac Surg       Date:  2019-05

6.  Visualization of Human Aortic Valve Dynamics Using Magnetic Resonance Imaging with Sub-Millisecond Temporal Resolution.

Authors:  Zheng Zhong; Kaibao Sun; Guangyu Dan; Qingfei Luo; Afshin Farzaneh-Far; Meryem Muge Karaman; Xiaohong Joe Zhou
Journal:  J Magn Reson Imaging       Date:  2021-03-24       Impact factor: 5.119

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.