Literature DB >> 7714372

Temperature dependence of canine brain tissue diffusion coefficient measured in vivo with magnetic resonance echo-planar imaging.

J MacFall1, D M Prescott, E Fullar, T V Samulski.   

Abstract

The intensity of conventional spin-echo diffusion-weighted magnetic resonance (MR) images is approximately linearly dependent on temperature over a restricted range using conventional diffusion-weighted spin-echo magnetic resonance imaging (MRI). However, conventional diffusion-weighted MRI is too motion sensitive for in vivo thermometry. The present work evaluated rapid diffusion-weighted echo-planar imaging (EPI), which is less sensitive to motion, for application to non-invasive thermometry in acrylamide gel materials and in vivo in canine brain tissue for applications in therapeutic hyperthermia. The rapidly switched, strong gradients needed for EPI were achieved using a 'local' z-axis gradient coil. Gel materials were heated with a small (10 cm diameter) spiral surface microwave (MW) applicator at 433 MHz, while in vivo heating was accomplished with whole body RF hyperthermia using an annular phased array (130 MHz). The MW or RF fields associated with heating and imaging (64 MHz) were decoupled using bandpass filters providing isolation in excess of 100 dB. This isolation was sufficient to allow simultaneous imaging and MW or RF heating without deterioration of the image signal-to-noise ratio. Using this system in a gel, temperature sensitivity of the diffusion coefficient was observed to be (3.04 +/- 0.03)%/degrees C which allowed temperature changes of 0.55 degrees C to be resolved for a 1.8 cm3 region in < 10 s of data acquisition. In vivo, cardiac gating of the pulse sequence was necessary to minimize motion artifacts in the brain. The temperature sensitivity of brain tissue was (1.9 +/- 0.1)%/degrees C allowing temperature changes of 0.9 degrees C to be resolved in a 0.9 cm3 volume in < 10 s of data acquisition. We conclude that with further optimization of the data acquisition conditions it will be possible to determine 0.5 degrees C temperature changes in 1 cm3 volumes in < 10 s using this technique.

Entities:  

Mesh:

Year:  1995        PMID: 7714372     DOI: 10.3109/02656739509004949

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  8 in total

1.  MR monitoring of tumour thermal therapy.

Authors:  D Germain; P Chevallier; A Laurent; H Saint-Jalmes
Journal:  MAGMA       Date:  2001-08       Impact factor: 2.310

Review 2.  Laser ablation of hepatocellular carcinoma--a review.

Authors:  Antony Lawrence Gough-Palmer; Wladyslaw Michal Witold Gedroyc
Journal:  World J Gastroenterol       Date:  2008-12-21       Impact factor: 5.742

3.  Multiresolution MRI temperature monitoring in a reduced field of view.

Authors:  Mohammed H Aljallad; Jing Yuan; Magdalini C Pilatou; Nathan J McDannold; Lawrence P Panych
Journal:  Magn Reson Imaging       Date:  2011-09-09       Impact factor: 2.546

4.  Theranostics with multifunctional magnetic gold nanoshells: photothermal therapy and t2* magnetic resonance imaging.

Authors:  Marites P Melancon; Andrew Elliott; Xiaojun Ji; Anil Shetty; Zhi Yang; Mei Tian; Brian Taylor; R Jason Stafford; Chun Li
Journal:  Invest Radiol       Date:  2011-02       Impact factor: 6.016

5.  [Thermometry by measuring the chemical shift of lanthanide complex].

Authors:  P Konstanczak; P Wust; B Sander; S Schründer; T Frenzel; W Wlodarczyk; T Vogl; G Müller; R Felix
Journal:  Strahlenther Onkol       Date:  1997-02       Impact factor: 4.033

Review 6.  Challenges to effective cancer nanotheranostics.

Authors:  Marites P Melancon; R Jason Stafford; Chun Li
Journal:  J Control Release       Date:  2012-08-18       Impact factor: 9.776

7.  Real-time MRI-guided hyperthermia treatment using a fast adaptive algorithm.

Authors:  Vadim L Stakhursky; Omar Arabe; Kung-Shan Cheng; James Macfall; Paolo Maccarini; Oana Craciunescu; Mark Dewhirst; Paul Stauffer; Shiva K Das
Journal:  Phys Med Biol       Date:  2009-03-13       Impact factor: 3.609

8.  Laser ablation for small hepatocellular carcinoma.

Authors:  Claudio Maurizio Pacella; Giampiero Francica; Giovanni Giuseppe Di Costanzo
Journal:  Radiol Res Pract       Date:  2011-12-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.