Literature DB >> 7713954

Comparison of bone-implant interface shear strength of hydroxyapatite-coated and alumina-coated metal implants.

T Inadome1, K Hayashi, Y Nakashima, H Tsumura, Y Sugioka.   

Abstract

We performed a transcortical push-out test to determine the effect of surface roughness of hydroxyapatite (HA)-coated implants on bone-implant shear strength in a canine model. Hydroxyapatite- and alumina-coated SUS316L with the same surface roughness (roughness average: Ra = 5 microns) and HA-coated Ti-6A1-4V (Ra = 8.4 microns), sintered HA (Ra = 0.9 micron), and dense alumina (Ra = 1.3 microns) were inserted into the dog's femur. The interface shear strength of the dense alumina was significantly lower than that of other implants at both 4 and 12 weeks after implantation. At 4 weeks after implantation, the interface shear strength of the alumina-coated SUS316L was significantly lower than that of other implants (P < .05) except the dense alumina, but at 12 weeks, there was no significant difference between the implant types except the dense alumina. This indicates that the surface roughness of the HA coating affects the enhancement of the bone-implant interface shear strength at the early period after implantation, and that a surface roughness of several micrometers does not influence the bond strength between bone and HA. A scanning electron microscopic study indicated that in almost all cases at 12 weeks, the failure site after push-out testing was the coating-substrate interface, not the coating-bone interface. Therefore, protection of the coating-substrate interface from direct shear loading is needed.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7713954     DOI: 10.1002/jbm.820290104

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  6 in total

1.  Histomorphological study of bone response to hydroxyapatite coating on stainless steel.

Authors:  A Merolli; A Moroni; C Faldini; P Tranquilli Leali; S Giannini
Journal:  J Mater Sci Mater Med       Date:  2003-04       Impact factor: 3.896

2.  The influence of residual stress on the shear strength between the bone and plasma-sprayed hydroxyapatite coating.

Authors:  Yung-Chin Yang; Chyun-Yu Yang
Journal:  J Mater Sci Mater Med       Date:  2007-08-15       Impact factor: 3.896

3.  Fixation of carbon fibre-reinforced carbon composite implanted into bone.

Authors:  M Lewandowska-Szumieł; J Komender; A Górecki; M Kowalski
Journal:  J Mater Sci Mater Med       Date:  1997-08       Impact factor: 3.896

4.  Analysis of push-out test data based on interfacial fracture energy.

Authors:  J I Thompson; P J Gregson; P A Revell
Journal:  J Mater Sci Mater Med       Date:  1999-12       Impact factor: 3.896

Review 5.  Bioactive Glass and Silicate-Based Ceramic Coatings on Metallic Implants: Open Challenge or Outdated Topic?

Authors:  Giulia Brunello; Hamada Elsayed; Lisa Biasetto
Journal:  Materials (Basel)       Date:  2019-09-10       Impact factor: 3.623

6.  Accuracy of different electronic torque drivers: A comparative evaluation.

Authors:  Byeong-Dae Ko; KeunBaDa Son; Seok Hyon Kang; Kyu-Bok Lee
Journal:  J Adv Prosthodont       Date:  2019-12-18       Impact factor: 1.904

  6 in total