Impact of heat and moisture exchangers on ventilatory pattern and respiratory mechanics in spontaneously breathing patients.

G Natalini1, P Bardini, N Latronico, A Candiani.   

Abstract

The upper airways warm and saturate inspired air with water vapour. In intubated or tracheotomized patients, this function is replaced either by hot water humidifiers or by heat and moisture exchangers (HMEs). The aim of this study was to quantify the modifications of ventilatory mechanics and patients' work when two different HMEs were added to spontaneously breathing patients. We studied nine consecutive patients with no previous history of chronic obstructive lung disease. All patients had been weaned from mechanical ventilation. They were breathing through devices supplying positive end-expiratory pressure and/or O2 enrichment. Two different HMEs were used: Icor Mediflux 1 and Icor Mediflux 2. These HMEs have identical chemical composition and configuration, but the Mediflux 1 is larger than the Mediflux 2. The humidification of the inspired gases was obtained alternatively by an active humidifier and the two HMEs. Data regarding ventilatory pattern and respiratory mechanics were collected by pulmonary monitor CP100 (Bicore). Tidal volume, work of breathing and pressure-time product were greater with Mediflux 1 than with Mediflux 2 or active humidifier. There were no significant differences in respiratory rate, intrinsic positive end-expiratory pressure (PEEPi), rapid shallow breathing index, arterial CO2 and O2 partial pressure. The larger HME (Mediflux 1) increased patient's effort, with no evidence of patient discomfort. However, the smaller HME (Mediflux 2) did not add a detectable load and provided adequate humidification. In conclusion, the smaller HME appears to be preferable for the management of spontaneously breathing patients.

Entities:  

Mesh:

Year:  1994        PMID: 7711718

Source DB:  PubMed          Journal:  Monaldi Arch Chest Dis        ISSN: 1122-0643


  3 in total

1.  Influence of the humidification device during acute respiratory distress syndrome.

Authors:  Gwénaël Prat; Anne Renault; Jean-Marie Tonnelier; David Goetghebeur; Emmanuel Oger; Jean-Michel Boles; Erwan L'Her
Journal:  Intensive Care Med       Date:  2003-08-06       Impact factor: 17.440

2.  Mechanical effects of heat-moisture exchangers in ventilated patients.

Authors:  G A Iotti; M C Olivei; A Braschi
Journal:  Crit Care       Date:  1999-09-23       Impact factor: 9.097

3.  Influence of heat and moisture exchanger use on measurements performed with manovacuometer and respirometer in healthy adults.

Authors:  Jeanette Janaina Jaber Lucato; Thiago Marraccini Nogueira da Cunha; Sara Solange Oliveira Costa Rocha; Fernanda Maria Palmieri de Carvalho; Daniele Cristina Botega; Jamili Anbar Torquato; Ana Cristina Gimenes; Renato Fraga Righetti
Journal:  Multidiscip Respir Med       Date:  2015-12-19