Percutaneous gastrostomy guided by ultrasound and fluoroscopy.

T Lorentzen1, B Skjoldbye, C Nolsøe, S Torp-Pedersen, T Mygind.   

Abstract

Percutaneous gastrostomy, utilizing a dedicated catheterization kit, with a combination of ultrasonographic (US) and fluoroscopic guidance, was carried out in 27 patients. The main indication for gastrostomy was the need for nutritional support in malignant esophageal stricture. After distending the stomach with water via a nasogastric tube, the gastric antrum was punctured under US guidance and a guide wire was inserted, followed by fluoroscopically guided tract dilatation and insertion of a 2.5-mm Cope-loop catheter. In all patients but one (96%) the procedure was successfully completed in one or 2 attempts. Two complications occurred: one case of a small subcutaneous abscess near the puncture site, and one late incident of dislodgement of a catheter without string-loop fixation, which had been inserted at a catheter exchange after 6 weeks. Percutaneous gastrostomy guided by US and fluoroscopy is a safe and efficacious alternative to endoscopic and surgical gastrostomy.

Entities:  

Mesh:

Year:  1995        PMID: 7710796

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  1 in total

1.  Re: Tips and tricks of percutaneous gastrostomy under image guidance in patients with limited access.

Authors:  Pierre-Yves Marcy; Alexis Lacout; Andrea Figl; Juliette Thariat
Journal:  Korean J Radiol       Date:  2011-08-24       Impact factor: 3.500