OBJECTIVE: To determine and compare the incidence of atonic pupil following modern extracapsular cataract extraction and small-incision phacoemulsification with lens implantation in a large series of consecutive patients. PATIENTS AND
DESIGN: A retrospective review was undertaken of 1283 consecutive cases of cataract surgery with posterior chamber intraocular lens implantation (919 extracapsular and 364 small-incision phacoemulsification) performed by two surgeons between October 30, 1991, and June 30, 1993. Postoperative atonic pupil was defined as a pupil that, following cataract surgery, was 6 mm or more in diameter and minimally or nonreactive to light, accommodation, or 1% pilocarpine hydrochloride.
RESULTS: Postoperatively, 25 (1.95%) of 1283 eyes developed an atonic pupil following cataract extraction with posterior chamber intraocular lens implantation (21 [2.29%] of 919 extracapsular and four [1.10%] of 364 phacoemulsification procedures). When an atonic pupil was present following surgery, disturbing glare often resulted, despite a well-centered intraocular lens.
CONCLUSIONS: To our knowledge, this is the first large, consecutive study of the incidence of atonic pupil following modern cataract surgery and the first study to compare the incidence of atonic pupil following extracapsular surgery vs small-incision phacoemulsification. Although the incidence of atonic pupil may be lower following phacoemulsification, caution is advised in the implantation of ever-smaller optic lenses.

Entities:  

Mesh:

Year:  1995        PMID: 7710394     DOI: 10.1001/archopht.1995.01100040064028

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  6 in total

Review 1.  [Efferent pupillary defects : Anisocoria and impaired light reaction].

Authors:  H Wilhelm; C Kelbsch
Journal:  Ophthalmologe       Date:  2017-01       Impact factor: 1.059

2.  Combined cataract and glaucoma surgery: the effect of pupil enlargement on surgical outcomes (an American Ophthalmological Society thesis).

Authors:  L Jay Katz; Camila Zangalli; Raymond Clifford; Benjamin Leiby
Journal:  Trans Am Ophthalmol Soc       Date:  2013-09

Review 3.  [Prosthetic iris devices].

Authors:  J Wolff
Journal:  Ophthalmologe       Date:  2011-08       Impact factor: 1.059

Review 4.  Topical nonsteroidal anti-inflammatory drugs for ophthalmic use: a safety review.

Authors:  Bruce I Gaynes; Richard Fiscella
Journal:  Drug Saf       Date:  2002       Impact factor: 5.606

5.  [Aniridia intraocular lenses in eyes with traumatic iris defects].

Authors:  K Schmitz; A Viestenz; D Meller; W Behrens-Baumann; K-P Steuhl
Journal:  Ophthalmologe       Date:  2008-08       Impact factor: 1.059

6.  Tonic pupil following pars plana vitrectomy and endolaser.

Authors:  Benyamin Ebrahim; Larry Frohman; Marco Zarbin; Neelakshi Bhagat
Journal:  Case Rep Med       Date:  2009-07-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.