Literature DB >> 7709628

Microparticle enzyme immunoassay (MEIA) for toxoplasma specific immunoglobulin G in comparison to the Sabin-Feldman dye test. A pilot study.

M Hayde1, H R Salzer, G Gittler, H Aspöck, A Pollak.   

Abstract

The microparticle enzyme immunoassay (MEIA) for detection of Toxoplasma specific IgG antibodies was compared to the Sabin-Feldman dye test (DT) as reference in 843 serum samples from a cohort of 757 pregnant women. The overall correlation for individual measurements was highly significant (R = 0.9446, p < 0.0001). DT and specific IgM combined allowed definition of 3 groups of patients: group 1 (no infection), group 2 (latent infection), group 3 (acute infection). A significant difference was found between the groups for the corresponding IgG values, as determined by the MEIA method, which allowed the following cut-off points to be laid down: group 1: 0-5.2 IU/ml, group 2: 5.3-187.5, and group 3: 187.6 IU/ml and higher. The validity of the cut-off points was tested in a subgroup of 57 patients who underwent serological follow-up during pregnancy. All 15 acutely- and 14 non-infected women, as well as 25 out of 28 latent infections were identified correctly. 3 latent infection were allocated falsely as acute. The threshold values presented in this report need to be confirmed in a large prospective study.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7709628

Source DB:  PubMed          Journal:  Wien Klin Wochenschr        ISSN: 0043-5325            Impact factor:   1.704


  4 in total

1.  Detection of immunoglobulin G (IgG) and IgM antibodies to Toxoplasma gondii: evaluation of four commercial immunoassay systems.

Authors:  W T Hofgärtner; S R Swanzy; R M Bacina; J Condon; M Gupta; P E Matlock; D L Bergeron; J J Plorde; T R Fritsche
Journal:  J Clin Microbiol       Date:  1997-12       Impact factor: 5.948

2.  Detection of toxoplasma-specific immunoglobulin G in human sera: performance comparison of in house Dot-ELISA with ECLIA and ELISA.

Authors:  Aref Teimouri; Mohammad Hossein Modarressi; Saeedeh Shojaee; Mehdi Mohebali; Nima Zouei; Mostafa Rezaian; Hossein Keshavarz
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2018-05-08       Impact factor: 3.267

3.  Evaluation of the liaison automated testing system for diagnosis of congenital toxoplasmosis.

Authors:  Andrea-Romana Prusa; Michael Hayde; Arnold Pollak; Kurt R Herkner; David C Kasper
Journal:  Clin Vaccine Immunol       Date:  2012-09-26

4.  Evaluation of the Vitros ECiQ immunodiagnostic system for detection of anti-Toxoplasma immunoglobulin G and immunoglobulin M antibodies for confirmatory testing for acute Toxoplasma gondii infection in pregnant women.

Authors:  David C Kasper; Andrea R Prusa; Michael Hayde; Nicole Gerstl; Arnold Pollak; Kurt R Herkner; Rosmarie Reiter-Reisacher
Journal:  J Clin Microbiol       Date:  2008-11-05       Impact factor: 5.948

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.