Monte Carlo calculated stem effect correction for NE2561 and NE2571 chambers in medium-energy x-ray beams.

C M Ma1, A E Nahum.   

Abstract

This paper presents the stem effect correction factors for the NE2561 and NE2571 ionization chambers calibrated in air and used at a depth in a phantom irradiated by medium-energy x-ray beams. The in air and in phantom stem effect correction factors were calculated as the ratios of the absorbed dose in the air cavity of an ionization chamber without and with a chamber stem. The 'global' stem correction factor was then calculated as the ratio of the in phantom correction factor to the in air correction factor. The calculations were carried out using the EGS4 (electron gamma shower version 4) Monte Carlo code system together with the use of a correlated sampling variance reduction technique. The results show that in general the chamber stem increases the chamber response in air but decreases it in phantom. For an NE2571 chamber the 'global' stem effect correction factor varies from 1.014 +/- 0.001 at 70 kV (2.9 mm A1, 0.1 mm Cu) to 1.005 +/- 0.001 at 300 kV (21.5 mm A1, 5.1 mm Cu) while for an NE2561 chamber it varies from 1.039 +/- 0.002 to 1.010 +/- 0.002 for the same kilovoltage and HVL values. In a 60Co beam the global stem correction is 1.001 +/- 0.001 for an NE2571 chamber and 1.003 +/- 0.001 for an NE2561 chamber. This is consistent with recent experimental results.

Entities:  

Mesh:

Year:  1995        PMID: 7708844     DOI: 10.1088/0031-9155/40/1/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  A virtual source model for Monte Carlo simulation of helical tomotherapy.

Authors:  Jiankui Yuan; Yi Rong; Quan Chen
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

2.  Percent depth-dose distribution discrepancies from very small volume ion chambers.

Authors:  Vikren Sarkar; Brian Wang; Hui Zhao; Bart Lynch; Joshua A James; Kiernan T McCullough; Bill J Salter
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

3.  Physico-chemical evaluation of rationally designed melanins as novel nature-inspired radioprotectors.

Authors:  Andrew D Schweitzer; Robertha C Howell; Zewei Jiang; Ruth A Bryan; Gary Gerfen; Chin-Cheng Chen; Dennis Mah; Sean Cahill; Arturo Casadevall; Ekaterina Dadachova
Journal:  PLoS One       Date:  2009-09-30       Impact factor: 3.240

4.  Monte Carlo investigation of collapsed versus rotated IMRT plan verification.

Authors:  Elaine Conneely; Andrew Alexander; Russell Ruo; Eunah Chung; Jan Seuntjens; Mark J Foley
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.