Literature DB >> 7708419

The first 500 patients with sacral anterior root stimulator implants: general description.

G S Brindley1.   

Abstract

The first 500 patients to have sacral anterior root stimulators implanted for bladder control are described. Of 479 survivors, 424 were using their stimulators when last followed up between 3 months and 16.1 years (mean 4 years) after implantation.

Entities:  

Mesh:

Year:  1994        PMID: 7708419     DOI: 10.1038/sc.1994.126

Source DB:  PubMed          Journal:  Paraplegia        ISSN: 0031-1758


  48 in total

Review 1.  TENS: a treatment option for bladder dysfunction.

Authors:  S E Bristow; S T Hasan; D E Neal
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  1996

2.  Repair, protection and regeneration of spinal cord injury.

Authors: 
Journal:  Neural Regen Res       Date:  2015-12       Impact factor: 5.135

3.  Bladder management for adults with spinal cord injury: a clinical practice guideline for health-care providers.

Authors: 
Journal:  J Spinal Cord Med       Date:  2006       Impact factor: 1.985

Review 4.  Spinal reflex control of micturition after spinal cord injury.

Authors:  Changfeng Tai; James R Roppolo; William C de Groat
Journal:  Restor Neurol Neurosci       Date:  2006       Impact factor: 2.406

5.  Inhibitory and excitatory perigenital-to-bladder spinal reflexes in the cat.

Authors:  Changfeng Tai; Bing Shen; Jicheng Wang; Michael B Chancellor; James R Roppolo; William C de Groat
Journal:  Am J Physiol Renal Physiol       Date:  2007-12-26

6.  Chronic infection of a Brindley sacral nerve root stimulator.

Authors:  Alexa Bramall; Bednash Chaudhary; Jamil Ahmad; Mohammed F Shamji
Journal:  BMJ Case Rep       Date:  2016-02-25

7.  Voiding reflex in chronic spinal cord injured cats induced by stimulating and blocking pudendal nerves.

Authors:  Changfeng Tai; Jicheng Wang; Xianchun Wang; James R Roppolo; William C de Groat
Journal:  Neurourol Urodyn       Date:  2007       Impact factor: 2.696

8.  Development of an Implantable Wireless and Batteryless Bladder Pressure Monitor System for Lower Urinary Tract Dysfunction.

Authors:  Yihua Zhong; Bolin Qian; Yaguang Zhu; Zhaohui Ren; Junming Deng; Jinghua Liu; Qianrui Bai; Xu Zhang
Journal:  IEEE J Transl Eng Health Med       Date:  2019-10-14       Impact factor: 3.316

9.  Impact of Bioelectronic Medicine on the Neural Regulation of Pelvic Visceral Function.

Authors:  William C de Groat; Changfeng Tai
Journal:  Bioelectron Med       Date:  2015-01-22

Review 10.  Neuroprostheses to treat neurogenic bladder dysfunction: current status and future perspectives.

Authors:  Nico J M Rijkhoff
Journal:  Childs Nerv Syst       Date:  2003-12-05       Impact factor: 1.475

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.