Literature DB >> 7706346

Prevention of fracture at the distal locking site of the gamma nail. A biomechanical study.

H Lacroix1, H Arwert, C J Snijders, W P Fontijne.   

Abstract

To investigate the origin of fractures at the distal locking site of the Gamma nail, we loaded ten paired human cadaver femora fixed with a Gamma nail in torsion until they fractured. When an awl was hammered in to start the hole for distal locking a fissure appeared in the lateral cortex of all the femora, and the mean torsional load to create a fracture was reduced by 57.8% compared with that in a control group in which the distal locking hole had been started with a centre drill. When an additional drill hole was made, the mean failure load in torsion decreased by 35.7%. We strongly recommend that an awl should not be used at the distal locking site of the Gamma nail; we recommend the use of a centre drill. Additional drill holes should be avoided because they act as stress raisers.

Entities:  

Mesh:

Year:  1995        PMID: 7706346

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  13 in total

1.  [Comparative stability evaluation of dynamic hip screw and gamma-nail osteosyntheses in unstable pertrochanteric femoral osteotomies].

Authors:  W Kaiser; J Burmester; H Hausmann; V Gulielmos; M Hätzel; H J Merker
Journal:  Langenbecks Arch Chir       Date:  1997

2.  Intramedullary fixation of intertrochanteric hip fractures: a comparison of two implant designs.

Authors:  Nicolas E Efstathopoulos; Vassilios S Nikolaou; John T Lazarettos
Journal:  Int Orthop       Date:  2006-05-31       Impact factor: 3.075

3.  3066 consecutive Gamma Nails. 12 years experience at a single centre.

Authors:  Alicja J Bojan; Claudia Beimel; Andreas Speitling; Gilbert Taglang; Carl Ekholm; Anders Jönsson
Journal:  BMC Musculoskelet Disord       Date:  2010-06-26       Impact factor: 2.362

4.  Biomechanical strain analysis of the proximal femur following retrograde intramedullary nailing.

Authors:  David J Hak; Rafael Neiman; Scott Hazelwood
Journal:  Curr Orthop Pract       Date:  2010-08-12

5.  Distal locked and unlocked nailing for perthrochanteric fractures--a prospective comparative randomized study.

Authors:  Xing Li; Liping Zhang; Zhiyong Hou; Zhao Meng; Wei Chen; Pengcheng Wang; Yingze Zhang
Journal:  Int Orthop       Date:  2015-04-26       Impact factor: 3.075

6.  Comparing two intramedullary devices for treating trochanteric fractures: a prospective study.

Authors:  Konstantinos G Makridis; Vasileios Georgaklis; Miltiadis Georgoussis; Vasileios Mandalos; Vasileios Kontogeorgakos; Leonidas Badras
Journal:  J Orthop Surg Res       Date:  2010-02-18       Impact factor: 2.359

7.  Is distal locking with IMHN necessary in every pertrochanteric fracture?

Authors:  Jirí Skála-Rosenbaum; Jan Bartonícek; Radek Bartoska
Journal:  Int Orthop       Date:  2009-11-01       Impact factor: 3.075

8.  [Fluoroscopy based surgical navitation vs. mechanical guidance system for percutaneous interventions. A controlled prospective study exemplified by distal locking of intramedullary nails].

Authors:  N Suhm; L A Jacob; I Zuna; P Regazzoni; P Messmer
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

9.  How evolution of the nailing system improves results and reduces orthopedic complications: more than 2000 cases of trochanteric fractures treated with the Gamma Nail System.

Authors:  R Pascarella; R Fantasia; A Maresca; C Bettuzzi; L Amendola; S Violini; F Cuoghi; P Sangiovanni; S Cerbasi; S Boriani; D S Tigani
Journal:  Musculoskelet Surg       Date:  2015-12-14

Review 10.  Distal Locked versus Unlocked Intramedullary Nailing in Intertrochanteric Fracture; A Systematic Review and Meta-Analysis of Randomized and Non-Randomized Trials.

Authors:  Dushyant Chouhan; Sanjay Meena; Kulbhushan Kamboj; Mukesh Kumar Meena; Amit Narang; Siddhartha Sinha
Journal:  Bull Emerg Trauma       Date:  2020-04
View more