Literature DB >> 7705123

The effect of short-term instillation of a mucolytic agent (mesna) on airway resistance in mechanically ventilated patients.

R Fernandez1, J Solé, L Blanch, A Artigas.   

Abstract

STUDY
OBJECTIVE: To determine whether bolus instillation of a mucolytic agent (mesna) could diminish airway resistance, endotracheal tube resistance, or both in patients mechanically ventilated for acute respiratory failure.
DESIGN: Randomized, double-blind, placebo-controlled, crossover trial.
SETTING: Medical-surgical ICU of a county hospital covering 350,000 inhabitants. PATIENTS: Twenty sedated and paralyzed patients with an endotracheal tube (ET) in place more than 72 h.
INTERVENTIONS: Data were recorded in three steps: (1) basal; (2) 10 min after endotracheal instillation of 3 mL of either saline solution or mesna; and (3) 10 min after instillation of the opposite drug. A 2-h washout period was allowed between data collection. MEASUREMENTS AND
RESULTS: We measured tidal volume (VT), inspiratory flow (VI), auto-PEEP, peak pressure (both at airway opening [Pmax.aw] and trachea [Pmax-.tr]) and plateau pressure (Pplat), and we calculated respiratory system compliance (Crs) and the inspiratory resistances of airways+tube (Rmax.aw), airways (Rmax.tr), and ET (Rtube). We found significant differences after the instillation of mesna compared with baseline in the following: airway plus tube resistance (Rmax.aw) (16.9 +/- 7.1 vs 18.9 +/- 7.7 cm H2O); airways resistance (Rmax.tr) (9.8 +/- 6.2 vs 12.0 +/- 6.4 cm H2O), PaO2 (96 +/- 28.5 vs 80 +/- 24.8 mm Hg), PaO2/PAO2 (0.360 +/- 0.152 vs 0.296 +/- 0.127), and PaCO2 (42 +/- 12.9 vs 43 +/- 14.1 mm Hg). We found no changes in compliance, auto-PEEP, and hemodynamics during the study. Instillation of saline solution had no effect on the physiologic variables studied.
CONCLUSIONS: In our patients, bolus tracheal instillation of mesna does not improve airway resistance; in fact, mesna instillation induces episodes of bronchospasm that disappear 2 h later.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7705123     DOI: 10.1378/chest.107.4.1101

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  2 in total

1.  Precision medicine and aerosolization in mechanically ventilated adults.

Authors:  Jordi Rello; Christian Domingo
Journal:  J Thorac Dis       Date:  2018-09       Impact factor: 2.895

2.  After myringotomy, can topical Mesna application be an alternative method to ventilation tube application?

Authors:  Rifat Karli; Fatih Ilkaya; Arzu Karli; Emre Gunbey; Harun Kucuk; Hasan Guzel; Emre Ayhan
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-02-08       Impact factor: 2.503

  2 in total