Literature DB >> 7698790

Filtering noncorrelated noise in impedance cardiography.

A K Barros1, M Yoshizawa, Y Yasuda.   

Abstract

Impedance cardiography (ICG) may be altered by noises as respiration and movement artifacts, mainly during exercise. In this work, a scaled Fourier linear combiner (SFLC) event-related to the R-R interval of ECG is proposed. It estimates the deterministic component of the impedance cardiographic signal and removes the noises uncorrelated to this interval. The impedance cardiographic signal is modeled as Fourier series with the coefficients estimated by the least mean square (LMS) algorithm. Simulations have been carried out to evaluate the filter performance for different noise conditions. Moreover, the method capability to remove uncorrelated noises was also examined in physiological data obtained in rest and exercise, by synchronizing respiration and pedaling with a metronome. Analyzing the ICG power spectrum, it was concluded that the proposed filter could remove the noises that are not synchronized with heart rate.

Mesh:

Year:  1995        PMID: 7698790     DOI: 10.1109/10.364522

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  8 in total

1.  Revisiting human cerebral blood flow responses to augmented blood pressure oscillations.

Authors:  J W Hamner; Keita Ishibashi; Can Ozan Tan
Journal:  J Physiol       Date:  2019-01-31       Impact factor: 5.182

2.  Automatic analysis of pre-ejection period during sleep using impedance cardiogram.

Authors:  Mohamad Forouzanfar; Fiona C Baker; Ian M Colrain; Aimée Goldstone; Massimiliano de Zambotti
Journal:  Psychophysiology       Date:  2019-03-05       Impact factor: 4.016

3.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

4.  Process techniques for human thoracic electrical bio-impedance signal in remote healthcare systems.

Authors:  Muhammad Zia Ur Rahman; Shafi Shahsavar Mirza
Journal:  Healthc Technol Lett       Date:  2016-06-13

5.  An open-source automated algorithm for removal of noisy beats for accurate impedance cardiogram analysis.

Authors:  Shafa-At Ali Sheikh; Amit Shah; Oleksiy Levantsevych; Majd Soudan; Jamil Alkhalaf; Ali Bahrami Rad; Omer T Inan; Gari D Clifford
Journal:  Physiol Meas       Date:  2020-08-11       Impact factor: 2.688

6.  Comparison of cardiovascular response to sinusoidal and constant lower body negative pressure with reference to very mild whole-body heating.

Authors:  Keita Ishibashi; Takafumi Maeda; Shigekazu Higuchi; Koichi Iwanaga; Akira Yasukouchi
Journal:  J Physiol Anthropol       Date:  2012-11-24       Impact factor: 2.867

7.  Visual information without thermal energy may induce thermoregulatory-like cardiovascular responses.

Authors:  Jun'ya Takakura; Takayuki Nishimura; Shigeki Watanuki
Journal:  J Physiol Anthropol       Date:  2013-12-28       Impact factor: 2.867

8.  Efficient reference-free adaptive artifact cancellers for impedance cardiography based remote health care monitoring systems.

Authors:  Madhavi Mallam; K Chandra Bhutan Rao
Journal:  Springerplus       Date:  2016-06-17
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.