Literature DB >> 7697246

Variability in the size of individual airways over the course of one year.

R H Brown1, E A Zerhouni, W Mitzner.   

Abstract

Several studies have examined the reproducibility over time of standard clinical measurements of pulmonary airways parameters, such as FEV1 and FVC. These studies indicate fairly consistent reproducibility of such measurements over periods of months and years. Although such traditional pulmonary function tests can provide quantitative measures of lung function, they do not provide any insight into the local or regional variation of individual airways. Therefore, in a longitudinal study in dogs, we directly measured the baseline size (cross-sectional area) of the same individual canine airways multiple times over a 1-yr period, using high-resolution computed tomography (HRCT). We compared the variability of individual airway size both within and between subjects to the various sizes of airways and to seasonal differences in size. Five anesthetized, intubated, and ventilated dogs were studied between five and eight times over a 15-mo period. HRCT scans were acquired at end expiration with the dogs at FRC on all occasions. All individual airways showed considerable variability in size over time as measured by the coefficient of variation (CV) (range: 9.2 to 69.3). The sizes of individual airways within a dog were seen to change by as much as twofold over time. Some dogs also showed significantly greater overall variability in airway size than did other dogs (p < 0.01), but this variability was related neither to the size of the airway (p = 0.34) nor to the season. These findings indicate a substantial local and regional variability in airway caliber that would not be detectable with conventional pulmonary function tests.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7697246     DOI: 10.1164/ajrccm.151.4.7697246

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  10 in total

Review 1.  HRCT imaging of airway responsiveness: effects of anesthetics.

Authors:  R H Brown
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

2.  Functional effect of longitudinal heterogeneity in constricted airways before and after lung expansion.

Authors:  C Wongviriyawong; R S Harris; H Zheng; M Kone; T Winkler; J G Venegas
Journal:  J Appl Physiol (1985)       Date:  2011-09-22

Review 3.  High resolution computed tomography in asthma.

Authors:  A N Mclean; M W Sproule; M D Cowan; N C Thomson
Journal:  Thorax       Date:  1998-04       Impact factor: 9.139

4.  Effects of airway tree asymmetry on the emergence and spatial persistence of ventilation defects.

Authors:  D Leary; T Winkler; A Braune; G N Maksym
Journal:  J Appl Physiol (1985)       Date:  2014-06-19

5.  Individual canine airway response variability to a deep inspiration.

Authors:  Robert H Brown; David W Kaczka; Katherine Fallano; Steve Shapiro; Wayne Mitzner
Journal:  Clin Med Insights Circ Respir Pulm Med       Date:  2011-02-14

6.  Peripheral resistance: a link between global airflow obstruction and regional ventilation distribution.

Authors:  C Wongviriyawong; R S Harris; E Greenblatt; T Winkler; J G Venegas
Journal:  J Appl Physiol (1985)       Date:  2012-11-01

7.  Temporal variability in the responses of individual canine airways to methacholine.

Authors:  Robert H Brown; David W Kaczka; Katherine Fallano; Sining Chen; Wayne Mitzner
Journal:  J Appl Physiol (1985)       Date:  2008-02-28

8.  Measurement of intraindividual airway tone heterogeneity and its importance in asthma.

Authors:  Robert H Brown; Alkis Togias
Journal:  J Appl Physiol (1985)       Date:  2016-04-21

9.  A mechanical design principle for tissue structure and function in the airway tree.

Authors:  Adam S LaPrad; Kenneth R Lutchen; Béla Suki
Journal:  PLoS Comput Biol       Date:  2013-05-30       Impact factor: 4.475

10.  Semi-automatic measurement of the airway dimension by computed tomography using the full-with-half-maximum method: a study of the measurement accuracy according to the orientation of an artificial airway.

Authors:  Namkug Kim; Joon Beom Seo; Koun Sik Song; Eun Jin Chae; Suk Ho Kang
Journal:  Korean J Radiol       Date:  2008 May-Jun       Impact factor: 3.500

  10 in total