Transcutaneous PO2 measurements in seriously ill newborn infants.

S Swanström, I Villa Elisaga, L Cardona, A Cárdenes, C Méndez-Bauer, G Rooth.   

Abstract

Continuous monitoring of oxygen tension using the transcutaneous electrode developed by Huch and co-workers was studied in severely ill newborn infants. Acceptable results were obtained despite the theoretical possibility that vasoconstriction might interfere with the method when used in the very ill. The reliability and clinical usefulness of the method is illustrated in 4 cases of severely ill newborn infants.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 769698      PMCID: PMC1545835          DOI: 10.1136/adc.50.12.913

Source DB:  PubMed          Journal:  Arch Dis Child        ISSN: 0003-9888            Impact factor:   3.791


  10 in total

1.  Catheter-tip transducer for continuous in-vivo measurement of oxygen tension.

Authors:  D Parker; A Key; R S Davies
Journal:  Lancet       Date:  1971-05-08       Impact factor: 79.321

2.  Reliability of transcutaneous monitoring of arterial PO2 in newborn infants.

Authors:  R Huch; W Lübbers; A Huch
Journal:  Arch Dis Child       Date:  1974-03       Impact factor: 3.791

3.  Transcutaneous measurement of blood Po2 (tcPo2) -- Method and application in perinatal medicine.

Authors:  R Huch; A Huch; D W Lübbers
Journal:  J Perinat Med       Date:  1973       Impact factor: 1.901

4.  Monitoring the intravascular Po2 in newborn infants.

Authors:  A Huch; R Huch; G Rooth
Journal:  J Perinat Med       Date:  1973       Impact factor: 1.901

5.  Quantitative continuous measurement of partial oxygen pressure on the skin of adults and new-born babies.

Authors:  R Huch; D W Lübbers; A Huch
Journal:  Pflugers Arch       Date:  1972       Impact factor: 3.657

6.  Continuous arterial oxygen tension monitoring in the newborn infant.

Authors:  T R Harris; M Nugent
Journal:  J Pediatr       Date:  1973-06       Impact factor: 4.406

7.  Continuous transcutaneous oxygen tension measured with a heated electrode.

Authors:  A Huch; R Huch; B Arner; G Rooth
Journal:  Scand J Clin Lab Invest       Date:  1973-05       Impact factor: 1.713

8.  Continuous intra-arterial P O2 measurements in infants.

Authors:  A Huch; R Huch; E Neumayer; G Rooth
Journal:  Acta Paediatr Scand       Date:  1972-11

9.  [Quantitative polarographic measurement of the oxygen pressure on the scalp of the newborn].

Authors:  A Huch; R Huch; D W Lübbers
Journal:  Arch Gynakol       Date:  1969

10.  Continuous O 2 monitoring of newborn and older infants and of children.

Authors:  J Strauss; A V Beran; R Baker
Journal:  J Appl Physiol       Date:  1972-08       Impact factor: 3.531

  10 in total
  1 in total

1.  In vivo response time of transcutaneous oxygen measurement to changes in inspired oxygen in normal adults.

Authors:  J T Brown; M S Schur; B C McClain; E R Kafer
Journal:  Can Anaesth Soc J       Date:  1984-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.