Literature DB >> 7696813

Nonsusceptibility artifacts due to metallic objects in MR imaging.

C R Camacho1, D B Plewes, R M Henkelman.   

Abstract

The authors investigated eddy current artifacts due to metallic objects within the magnetic resonance imaging field. The problem was simplified by using a circular copper loop as a model for the more complex eddy current pathways present in a metallic implant. With this simple geometry, the authors show that radio-frequency (RF)-induced eddy currents in the metal produce a significant local artifact. However, no appreciable artifacts due to the switching magnetic field gradients were observed. A detailed quantitative analysis of the mechanism of RF-induced eddy current artifact due to the the copper loop was performed. The artifact was demonstrated experimentally to result from perturbations of the transmit and receive sensitivities of the RF coil. Theoretical calculations of these perturbations showed excellent agreement with experimental results. With an understanding of the artifact mechanism, methods for correcting the RF-induced eddy current artifact were applied.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7696813     DOI: 10.1002/jmri.1880050115

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  26 in total

1.  MR-velocity mapping in vascular stents to assess peak systolic velocity. In vitro comparison of various stent designs made of Stainless Steel and Nitinol.

Authors:  Jacqueline van Holten; Patrik Kunz; Paul G H Mulder; Peter M T Pattynama; Hildo J Lamb; Lukas C van Dijk
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

2.  Radiofrequency heating and magnetically induced displacement of dental magnetic attachments during 3.0 T MRI.

Authors:  K Miyata; M Hasegawa; Y Abe; T Tabuchi; T Namiki; T Ishigami
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

3.  Mutual interferences and design principles for mechatronic devices in magnetic resonance imaging.

Authors:  Ningbo Yu; Roger Gassert; Robert Riener
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-09-02       Impact factor: 2.924

4.  MR angiographic evaluation of platinum coil packs at 1.5T and 3T: an in vitro assessment of artifact production: technical note.

Authors:  Matthew T Walker; Jerome Tsai; Todd Parish; Brian Tzung; Ali Shaibani; Elizabeth Krupinski; Eric J Russell
Journal:  AJNR Am J Neuroradiol       Date:  2005-04       Impact factor: 3.825

5.  Interaction between grounding pads used for RF ablation therapy and magnetic resonance imaging.

Authors:  Christina Schraml; Hansjörg Graf; Andreas Boss; Stephan Clasen; Martin Leibfritz; Philippe L Pereira; Claus D Claussen; Fritz Schick
Journal:  MAGMA       Date:  2005-12-13       Impact factor: 2.310

Review 6.  PET/MRI hybrid imaging: devices and initial results.

Authors:  Bernd J Pichler; Martin S Judenhofer; Hans F Wehrl
Journal:  Eur Radiol       Date:  2008-03-21       Impact factor: 5.315

Review 7.  Pre-clinical PET/MR: technological advances and new perspectives in biomedical research.

Authors:  Hans F Wehrl; Martin S Judenhofer; Stefan Wiehr; Bernd J Pichler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

8.  Contrast-Enhanced and Time-of-Flight MRA at 3T Compared with DSA for the Follow-Up of Intracranial Aneurysms Treated with the WEB Device.

Authors:  C Timsit; S Soize; A Benaissa; C Portefaix; J-Y Gauvrit; L Pierot
Journal:  AJNR Am J Neuroradiol       Date:  2016-04-21       Impact factor: 3.825

9.  Influence of dental materials on dental MRI.

Authors:  O Tymofiyeva; S Vaegler; K Rottner; J Boldt; A J Hopfgartner; P C Proff; E J Richter; P M Jakob
Journal:  Dentomaxillofac Radiol       Date:  2013-04-22       Impact factor: 2.419

Review 10.  Advanced MRI strategies for assessing spinal cord injury.

Authors:  Seth A Smith; James J Pekar; Peter C M van Zijl
Journal:  Handb Clin Neurol       Date:  2012
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.