Literature DB >> 7692414

Patient acceptance of the implantable cardioverter defibrillator in ventricular tachyarrhythmias.

B Lüderitz1, W Jung, A Deister, A Marneros, M Manz.   

Abstract

Besides surgical problems, recipients of implantable cardioverter defibrillators (ICDs) are faced with psychological and social adjustments. Successful ICD therapy is influenced by the patients' perceived concerns regarding device, discharge, changes in life style, and complications. In order to assess patients' acceptance of the ICD, the psychological profile of 57 consecutive patients was evaluated using a specifically designed questionnaire and the State Trait Anxiety Inventory (STAI). The results showed that 20 patients stated fear of ICD discharge, 12 patients revealed physical discomfort due to the device, and limited quality-of-life occurred in 8 patients. Fifty-five of 57 patients answered that it was worth having an ICD device implanted, 30 (53%) patients returned to active life, and 56 (98%) would advise another patient to undergo implantation if necessary. Overall, there was only a slight, but insignificant, decrease in the level of anxiety within the total patient population after ICD implantation. However, a comparison of two subgroups indicated that the state of anxiety was significantly higher in patients < 50 years of age as well as in patients having received > 5 shocks versus those > 50 years of age and having experienced < 5 shocks. In general, the acceptance of the ICD as a tool in managing life-threatening ventricular tachyarrhythmias is high. Besides the increased survival rate, quality-of-life and patient acceptance are important criteria for successful ICD therapy.

Entities:  

Mesh:

Year:  1993        PMID: 7692414     DOI: 10.1111/j.1540-8159.1993.tb01816.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  16 in total

Review 1.  Quality of life in atrial fibrillation.

Authors:  B Lüderitz; W Jung
Journal:  J Interv Card Electrophysiol       Date:  2000-01       Impact factor: 1.900

2.  Implantable cardioverter-defibrillator therapy: influence of left ventricular function on long-term results.

Authors:  H F Pitschner; J Neuzner; E Himmrich; A Liebrich; J Jung; A Heisel
Journal:  J Interv Card Electrophysiol       Date:  1997-11       Impact factor: 1.900

3.  How different from pacemaker patients are recipients of implantable cardioverter-defibrillators with respect to psychosocial adaptation, affective disorders, and quality of life?

Authors:  F Duru; S Büchi; R Klaghofer; H Mattmann; T Sensky; C Buddeberg; R Candinas
Journal:  Heart       Date:  2001-04       Impact factor: 5.994

4.  Views of patients with heart failure about their role in the decision to start implantable cardioverter defibrillator treatment: prescription rather than participation.

Authors:  Anders Agård; Rurik Löfmark; Nils Edvardsson; Inger Ekman
Journal:  J Med Ethics       Date:  2007-09       Impact factor: 2.903

5.  Determinants of the quality of life (QoL) in patients with an implantable cardioverter/defibrillator (ICD).

Authors:  F Godemann; C Butter; F Lampe; M Linden; S Werner; S Behrens
Journal:  Qual Life Res       Date:  2004-03       Impact factor: 4.147

6.  Cardiac transplantation in a patient with emotionally triggered implantable cardioverter defibrillator storms.

Authors:  Chirine Parsai; Robert F Bonvini; Bruno Schnetzler; Henri Sunthorn
Journal:  Heart Vessels       Date:  2007-09-20       Impact factor: 2.037

7.  An unusual resolution of T-wave oversensing in an implantable cardioverter defibrillator in a child with long QT syndrome.

Authors:  Mitchell I Cohen; Petros V Anagnostopoulos; Andrew Papez
Journal:  J Interv Card Electrophysiol       Date:  2009-01-16       Impact factor: 1.900

8.  Effect of a psychoeducational intervention on depression, anxiety, and health resource use in implantable cardioverter defibrillator patients.

Authors:  Sandra B Dunbar; Jonathan J Langberg; Carolyn M Reilly; Bindu Viswanathan; Frances McCarty; Steven D Culler; Marian C O'Brien; William S Weintraub
Journal:  Pacing Clin Electrophysiol       Date:  2009-10       Impact factor: 1.976

9.  Predictors and clinical impact of inappropriate implantable cardioverter-defibrillator shocks in Korean patients.

Authors:  Jeong Hoon Yang; Kyeongmin Byeon; Hye Ran Yim; Jung Wae Park; Seung-Jung Park; June Huh; June Soo Kim; Young Keun On
Journal:  J Korean Med Sci       Date:  2012-05-26       Impact factor: 2.153

10.  Prospective multicenter randomized trial of fast ventricular tachycardia termination by prolonged versus conventional anti-tachyarrhythmia burst pacing in implantable cardioverter-defibrillator patients-Atp DeliVery for pAiNless ICD thErapy (ADVANCE-D) Trial results.

Authors:  Massimo Santini; Maurizio Lunati; Pascal Defaye; Johann Mermi; Alessandro Proclemer; Silvia del Castillo-Arroys; Giulio Molon; Elisabetta Santi; Tiziana De Santo; Xavier Navarro; Axel Kloppe
Journal:  J Interv Card Electrophysiol       Date:  2010-01-20       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.